C. Installation<br />
Attention!<br />
Remove the securing pin from cable slack or cable<br />
safety device on both sides!<br />
• Insert the safety contact (D) into the housing of cable slack or cable<br />
safety device.<br />
• Screw it on.<br />
• Release the outer PG-nuts on both housings.<br />
• Push nut over flat cable of the switches.<br />
• Insert flat cables through sealing.<br />
• Screw the nuts on again.<br />
For versions with closing edge safety device:<br />
• Cut the bottom sealing as shown in fig. 13.1 or 13.2<br />
• Receiver = black = side of control unit<br />
Transmitter = grey = opposite side<br />
Insert the optosensors into the sealing.<br />
• The connecting cables shall be led through the punched opening in<br />
bottom sealing.<br />
• Guide the connecting cable (G) through the upper tube of the bottom<br />
sealing.<br />
• It shall be let out again through the punched opening in bottom door<br />
seal.<br />
• Release the middle PG-nut.<br />
• Push PG-nut over flat cable.<br />
• Insert flat cables through sealing.<br />
• Screw the nuts on again.<br />
• Connect the plugs on both sides according to the printed symbols.<br />
English Page 16