No.<br />

1<br />

No.<br />

1<br />

OPERATION INDICATOR<br />

(POWER) (AIR PURIFYING)<br />

Abnormal<br />

point<br />

MXZ <strong>type</strong><br />

Operation<br />

mode<br />

setting<br />

Operation indicator lamp Symptom Condition Remedy<br />

• AIR PURIFYING lamp fl ash.<br />

2.5-second OFF<br />

• POWER lamp is lighted.<br />

OPERATION INDICATOR<br />

(POWER) (AIR PURIFYING)<br />

Abnormal<br />

point<br />

AIR<br />

PURIFYING<br />

power<br />

control<br />

10-5. TROUBLE CRITERION OF MAIN PARTS<br />

<strong>MSZ</strong>-<strong>FH25VE</strong> <strong>MSZ</strong>-FH35VE<br />

Outdoor unit<br />

operates but<br />

indoor unit does<br />

not operate.<br />

The operation mode of the each indoor unit is<br />

differently set to COOL (includes DRY, FAN)<br />

and HEAT at the same time, the operation<br />

mode of the indoor unit that has operated at<br />

fi rst has the priority.<br />

25<br />

• Unify the operation mode.<br />

Refer to outdoor unit service<br />

manual.<br />

Part name Check method and criterion Figure<br />

Room temperature Measure the resistance with a tester.<br />

thermistor (RT11)<br />

Indoor coil thermistor<br />

(RT12, RT13)<br />

Refer to 10-7. "Test point diagram and voltage", "Indoor electronic control<br />

P.C. board", for the chart of thermistor.<br />

Indoor fan motor (MF) Check 10-6. "Check of indoor fan motor".<br />

Vane motor (MV1)<br />

(HORIZONTAL)<br />

Vane motor (MV2)<br />

(VERTICAL)<br />

i-see SENSOR MOTOR<br />

(MT)<br />

AIR PURIFYING power Check 10-6. .<br />

OBH623<br />

Operation indicator lamp Symptom Condition Remedy<br />

AIR PURIFYING lamp fl ashes.<br />

2.5-second OFF<br />

Lighted<br />

Blinking<br />

Not lighted<br />

Lighted<br />

Blinking<br />

Not lighted<br />

Indoor unit and<br />

outdoor unit do<br />

not operate.<br />

When AIR PURIFYING power cannot be<br />

turned OFF even if the AIR PURIFYING<br />

operation is turned OFF by remote controller.<br />

Measure the resistance between the terminals with a tester.<br />

(Temperature: 10 - 30°C)<br />

Color of the lead wire Normal<br />

RED - SKY 262 - 328 Ω<br />

Measure the resistance between the terminals with a tester.<br />

(Temperature: 10 - 30°C)<br />

Color of the lead wire Normal<br />

RED - SKY 219 - 273 Ω<br />

Measure the resistance between the terminals with a tester.<br />

(Temperature: 10 - 30°C)<br />

Color of the lead wire Normal<br />

RED - BLK 262 - 328 Ω<br />

• Refer to 10-6. "Check of AIR<br />

PURIFYING power".<br />

SKY<br />

SKY<br />

RED<br />

SKY<br />

SKY<br />

RED<br />

BLK<br />

BLK<br />

RED<br />

ROTOR<br />

SKY SKY<br />

ROTOR<br />

SKY SKY<br />

ROTOR<br />

BLK BLK