crimping, interconnecting cables, harnesses, and wiring - NASA
crimping, interconnecting cables, harnesses, and wiring - NASA
crimping, interconnecting cables, harnesses, and wiring - NASA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FIGURE A-25<br />
FIGURE A-26<br />
CRIMPS: INSULATION CLEARANCE<br />
Page 107 of 114<br />
<strong>NASA</strong>-STD-8739.4 with Change 6<br />
MINIMUM CONDUCTOR EXPOSURE<br />
Insulation terminates 0.010 in. minimum from<br />
contact crimp barrel.<br />
MAXIMUM CONDUCTOR EXPOSURE<br />
Amount of exposed bare wire between the<br />
insulation <strong>and</strong> the contact crimp barrel does not<br />
exceed 0.03 inch maximum for No. 20 AWG wire<br />
<strong>and</strong> smaller, <strong>and</strong> 0.05 inch maximum for No. 18<br />
AWG wire <strong>and</strong> larger.