Chapter 5 - <strong>Repeater</strong> Programming By DTMF Tone<br />
This chapter describes how the <strong>CAT</strong>-<strong>300</strong> controller is programmed by the repeater<br />
owner using a DTMF keypad. The various types of program commands are described<br />
in detail and examples are given in the following text.<br />
Initialization<br />
To initialize the <strong>CAT</strong>-<strong>300</strong>, set dipswitch #7 to ON and cycle DC power. During<br />
power-up, the voice will say: "RESET DATA LOAD COMPLETED." Set dip-switch #7<br />
to OFF. Initialization consists of following operations:<br />
Dip-switch #7 Initialization<br />
1. All memory locations are cleared.<br />
2. The control channels marked with an [*] are enabled.<br />
3. The unlock number is loaded with the default value [1234567].<br />
5. The control operator prefix code is loaded with the default value [100].<br />
6. The control numbers are set to default values.<br />
7. The timers are set to default values.<br />
8. The voice message buffers are loaded with default messages.<br />
9. ID #1 is loaded with "<strong>CAT</strong> THREE HUNDRED REPEATER."<br />
10. ID #2 is loaded with "<strong>CAT</strong> THREE HUNDRED."<br />
11. All active memory saves are filled with default values.<br />
12. Load Hardware Input buffers with User Function Switch commands.<br />
Programming the Unlock Control Number<br />
To program the UNLOCK code, set dipswitch #8 to the ON position. The voice<br />
will say: "ENTER CONTROL." Key-up and enter a seven-digit number. Un-key, if<br />
the number is accepted, the voice will say: "DATA INPUTS OK." If the number is<br />
rejected, the voice will say: "ENTER CONTROL." Key-up and enter the seven-<br />
digit number. Set dipswitch #8 to the OFF position. NOTE: When the <strong>CAT</strong>-<strong>300</strong> is<br />
powered up with dipswitch #7 set to ON, the unlock number defaults to: [1-2-3-<br />
4-5-6-7]<br />
Unlocking the <strong>Controller</strong> By Radio<br />
To unlock the controller, key-up and enter the seven digit unlock number. The<br />
voice will say: "<strong>CAT</strong>-<strong>300</strong> CONTROL."<br />
Locking the <strong>Controller</strong> By Radio<br />
Key-up and send [*0]. Un-key, the controller will lock-up and the voice will<br />
say: "MANUAL EXIT." The <strong>CAT</strong>-<strong>300</strong> will lock-up automatically when the<br />
programming timer expires. The voice will say: "TIMER EXIT." The programming<br />
time limit can be set with the [*615*] programming command.<br />
Programming <strong>Controller</strong> By Telephone<br />
To program the <strong>CAT</strong>-<strong>300</strong>, call the repeater by telephone. When the <strong>CAT</strong>-<strong>300</strong><br />
answers, a beep will be heard. Enter the seven digit unlock number followed by<br />
a (#) pound. The voice will say: "<strong>CAT</strong>-<strong>300</strong> CONTROL." Programming by phone is<br />
identical to programming by radio except you must end each entry with a [#]<br />
pound. To terminate programming by phone send [*0#].<br />
NOTE: The <strong>CAT</strong>-<strong>300</strong> must be unlocked to perform the following procedures:<br />
5-1