Control - Prefix Number Memory<br />

This memory area is reserved for storage of control and prefix numbers. These<br />

numbers can be from one to seven digits and will change to a default value when<br />

the <strong>CAT</strong>-<strong>300</strong> is powered up with dip-switch #7 set to the ON position.<br />

Control Operator Prefix Number [*501*]<br />

This number must precede the command used to change the settings of the<br />

repeater's control channels in Zones 1 through 8. Example: To program a<br />

Control Operator Prefix Number of 100, key-up and send [*501*100], Un-key and<br />

the voice will say: "CONTROL OK." Access to this number should be limited to<br />

control operators.<br />

Time Request Number [*502*] [DX]<br />

This number must be entered to request the time of day announcement. Example:<br />

To program a Time Request Number of 400, key-up and send [*502*400]. Un-key<br />

and the voice will say: "CONTROL OK."<br />

Memory Recall Prefix [*503*]<br />

This number must precede the command used to execute a memory move from storage<br />

into active memory. Example: To program a Memory Recall Prefix Number of 175,<br />

key-up and send [*503*175], Un-key and the voice will say: "CONTROL OK."<br />

DTMF Access Number [*504*]<br />

When the repeater is in the DTMF Access Mode it will not respond to a COR<br />

input. The repeater user must enter a DTMF access number to activate the<br />

repeater. When the repeater returns to rest for a period determined by the<br />

sleep timer, the number must be re-entered to activate the repeater. Example:<br />

To program a DTMF Access Number of 325, key-up and send [*504*325]. Un-key and<br />

the voice will say: "CONTROL OK."<br />

DTMF Pad Test Number [*505*]<br />

This number must be entered to initiate a DTMF keypad test. Example: To<br />

program a DTMF Pad Test Number of 375, key-up and send [*505*375]. Un-key and<br />

the voice will say: "CONTROL OK."<br />

User Function Switch Number [*506*]<br />

This number must precede the command to change the settings of the user<br />

function switches on the <strong>CAT</strong>-<strong>300</strong>. Example: To program a User Function Switch<br />

Number of 550, key-up and send [*506*550]. Un-key and the voice will say:<br />

"CONTROL OK."<br />

Autopatch Access Number [*507*]<br />

This number must be entered to access the autopatch. Example: To program an<br />

autopatch access number of *, key-up and send [*507**]. Un-key and the voice<br />

will say: "CONTROL OK."<br />

Autopatch Disconnect Number [*508*]<br />

This number must be entered to terminate the autopatch. Example: To program<br />

an autopatch termination number of #, key-up and send [*508*#]. Un-key and the<br />

voice will say: "CONTROL OK."<br />