Swimming pools below<br />
ground level<br />
WaTERPRooFING SySTEM To PREvENT<br />
WaTER LoSS<br />
Dr. Fixit torchShielD<br />
SP 4160<br />
Methodology<br />
rAft slAb ANd exterNAl wAlls<br />
Surface Preparation<br />
The surface shall be cleaned thoroughly<br />
of all contaminants like dust, traces of<br />
curing compound, oil and grease. All surface<br />
imperfections, protrusions, structurally<br />
unsound and loose concrete must be removed<br />
and repaired with polymer modified mortar<br />
using Dr. Fixit Pidicrete URP.<br />
Priming<br />
All over the blinding concrete or PCC that is<br />
properly leveled, Dr. Fixit Torchshield Primer<br />
priming shall be done with a roller or brush,<br />
over a dried surface. Allow the primer to dry<br />
for 8 to 10 hrs.<br />
Application on PCC below raft slab<br />
Dr. Fixit Torchshield SP 4160, SBS based<br />
polyester reinforced membrane, shall be laid<br />
by providing an overlap of at least 100 mm. Dr.<br />
Fixit Torchshield SP 4160 shall be extended<br />
to maximum extend of the full area of the<br />
blinding concrete. Lay geotextile membrane<br />
of 120 gsm as a protection layer over Dr. Fixit<br />
Torchshield SP 4160 membrane. A scred<br />
of 50 mm must be overlaid in M 20 concrete<br />
grade, which will facilitates the reinforcement<br />
cage to be assemble, for the RCC raft to be<br />
cast over it.<br />
System Life<br />
Expectancy<br />
of 10 years<br />
Application on retaining wall<br />
Concrete joints in retaining walls and at raft<br />
level shall be provided with a swellable,<br />
compressible, adhesive strip Dr. Fixit Waterbar<br />
SW 2020 of 20 mm X 20 mm size, which shall<br />
be placed in joints while concreting of raft slab<br />
and retaining walls.<br />
40 mm X 40 mm sized angle fillets must<br />
be provided at the corners, all around the<br />
swimming pool floor and walls from external<br />
side.<br />
Prepare the retaining wall surface by cleaning<br />
and priming it with Dr. Fixit Torchshield<br />
Primer to receive waterproofing system.<br />
Apply Dr. Fixit Torchshield SP 4160 starting<br />
from the bottom of external wall, right up<br />
to the ground level. Ensure that Dr. Fixit<br />
Torchshield SP 4160 is applied up to at least<br />
300 mm above the ground level.<br />
After completion of application place a 4 mm<br />
thick bituminous protection board or a 12<br />
mm thick dimpled HDPE drainage boards for<br />
protection.<br />
Alternatively, Dr. Fixit Samshield XL<br />
1500/ 2100 can be used instead of Dr. Fixit<br />
Torchshield SP4160<br />
Dr. Fixit Torchshield Dr. Fixit Waterbar Dr. Fixit Pidicrete URP<br />
aPP / SBS modified bitumen<br />
based membrane<br />
Tough waterproofing system for below grade application<br />
1 PCC<br />
2 Dr. Fixit Torchshield Primer<br />
3 Dr. Fixit Torchshield SP 4160<br />
4 Geotextile fabric<br />
5 Screed<br />
6 Dr. Fixit Waterbar SW2020<br />
7 Protection Board<br />
Flexible adhesive waterstop strip SBR Latex for waterproofing & repairs<br />
SWP 10<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Swimming pools below<br />
ground level<br />
WaTERPRooFING SySTEM To PREvENT<br />
WaTER LoSS<br />
Dr. Fixit FaStFlex<br />
Methodology<br />
INterNAl AreA<br />
Surface Preparation<br />
The internal surface areas (horizontal and<br />
vertical) shall be cleaned thoroughly of all<br />
contaminants like dust, traces of curing<br />
compound, oil and grease. All surface<br />
imperfections, protrusions, structurally<br />
unsound and loose concrete must be removed<br />
and repaired with polymer modified mortar<br />
using Dr. Fixit Pidicrete URP.<br />
At internal side walls and raft junction cast 40<br />
mm X 40 mm sized angle fillets all around the<br />
swimming pool floor.<br />
Application<br />
After complete curing of the raft slab and<br />
retaining walls apply 1st coat of Dr. Fixit<br />
Fastflex maintaining the saturated surface dry<br />
condition.<br />
While the coat is still wet embed a glass fibre<br />
mesh of 2.5mm x 2.5 mm of 50 gsm over the<br />
angle fillets as a reinforcing strip and allow it<br />
to soak completely. Immediately apply one<br />
additional coat to sandwich this glass fibre<br />
mesh between the Dr. Fixit Fastflex coatings.<br />
Apply the 2nd coat of Dr. Fixit Fastflex.<br />
After the 2nd coat is completely dry apply 3rd coat of Dr. Fixit Fastflex and sprinkle coarse<br />
sand while it is still wet. This will provide the<br />
key for subsequent tile adhesive materials.<br />
System Life<br />
Expectancy<br />
of 10 years<br />
The inserts shall be wrapped around with<br />
Dr. Fixit Bathseal Tape to ensure a water-tight<br />
fitting. Light fitting casings, pipes, inserts, etc.,<br />
provided in the concrete raft floor and walls<br />
are to be grouted with a non-shrink grout,<br />
Dr. Fixit Bathseal Grout.<br />
Dr. Fixit Fastflex should be liberally applied<br />
around the insert pipes and the around the light<br />
fittings sandwiched with an open woven mesh<br />
to be extra precaution about these points.<br />
Tiles shall then be applied using tile adhesives<br />
from ROFF range depending upon whether<br />
they are glass mosaics, or ceramics.<br />
After the tile fixing fill the grooves / tile joints<br />
with epoxy based ROFF RTM tile grouts.<br />
Dr. Fixit Pidicrete URP Dr. Fixit Fastflex Dr. Fixit Bathseal Grout Dr. Fixit Bathseal Tape Roff RTM Epoxy<br />
SBR Latex for<br />
waterproofing & repairs<br />
High performance polymer<br />
modified cementitious<br />
coating<br />
Highly puncture resistant and tough below grade<br />
waterproofing membrane system<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Non-shrink grout for pipe<br />
fitting<br />
1 Binding Concrete (PCC)<br />
2 Dr. Fixit Torchshield Primer<br />
3 Dr. Fixit Torchshield AP 4160<br />
4 Geotextile<br />
5 Concrete screed<br />
6 Concrete raft slab<br />
7 Dr. Fixit Fastflex (2 coats)<br />
8 Dr. Fixit Fastflex (3 rd coat with sand)<br />
9 Roff NSA & Roff RTM Epoxy Grout<br />
10 Light fixture with Dr. Fixit Bathseal Grout<br />
11 Pipe opening with Dr. Fixit Bathseal Grout<br />
Leak-proof sealing tape for<br />
pipe wrapping<br />
11<br />
10<br />
Epoxy based tile joint filler<br />
SWP 10<br />
15