Terrace waterproofing<br />
with heat insulation<br />
WaTERPRooFING aND HEaT INSULaTIoN<br />
SySTEM FoR THE FLaT RooFS<br />
Dr. Fixit exteNSa,<br />
Dr. Fixit FoamShielD<br />
& Dr. Fixit<br />
Newcoat<br />
Surface Preparation<br />
The surface shall be cleaned thoroughly<br />
of all contaminants like dust, traces of<br />
curing compound, oil and grease. All surface<br />
imperfections, protrusions, structurally<br />
unsound and loose concrete must be removed<br />
and repaired with polymer modified mortar<br />
using Dr. Fixit Pidicrete URP.<br />
Priming<br />
Priming generally not required on concrete<br />
substrates for Dr. Fixit Extensa.<br />
Application<br />
Spray apply liquid, protective waterproofing<br />
coating, Dr. Fixit Extensa, over the entire slab<br />
area with a designated pump. It will act as a<br />
tough and excellent waterproofing barrier for<br />
the subsequent coat of Dr. Fixit Foamshield<br />
Then spray apply polyurethane foam Dr.<br />
Fixit Foamshield, of average thickness 35<br />
to 45 mm with a density of 50 kg per cu.m.<br />
approximately. This will harden for subsequent<br />
application over it.<br />
Brush apply protective acrylic waterproofing<br />
coating, Dr. Fixit Newcoat, over the entire<br />
PU Foam spread area, at approximately 300<br />
microns DFT.<br />
System Life<br />
Expectancy<br />
of 25 years<br />
Loosely lay geotextile fabric of 120 gsm, with<br />
overlap of 30 cm., after Dr. Fixit Newcoat dries<br />
Fix ridges in panels (area larger than 10 sq.m.<br />
& slope of 1 in 100 or 1 in 80), using bitumen<br />
impregnated boards & cement sand mortar.<br />
Lay or cast screed of concrete in M 20 in slope<br />
in 1: 100. Average thickness of screed is 75 to<br />
100 mm.<br />
The ridges of bitumen impregnated boards or<br />
polyboard will act as construction joints. Using<br />
the grinding wheel, expose the joints and form<br />
grooves.<br />
Fix backing rod & apply elastomeric<br />
polysulphide sealant, Dr. Fixit Pidiseal PS 42P<br />
in all grooves of the construction joints in the<br />
concrete screed<br />
Fix angle fillets in concrete along the parapet,<br />
mechanical duct openings & pre-utility up<br />
stands.<br />
Apply a final coat of Dr. Fixit Newcoat of 300<br />
micron DFT over the concrete screed & angle<br />
fillets (50 mm height) as a sealer coat, up to<br />
the flashing.<br />
Dr. Fixit Extensa Dr. Fixit Newcoat Dr. Fixit Pidicrete URP<br />
Highly elastomeric and puncture resistant<br />
waterproofing coating<br />
Highly energy efficient, extremely lightweight, high end<br />
waterproofing and insulating system<br />
Heavy duty reinforced acrylic waterproofing<br />
coating<br />
9<br />
8<br />
1 Slab<br />
2 Dr. Fixit Extensa<br />
3 Dr. Fixit Foamshield<br />
4 Dr. Fixit Newcoat<br />
5 Geotextile<br />
6 Screed<br />
7 Angle Fillet<br />
8 Dr. Fixit Newcoat<br />
9 Drip mould<br />
SBR Latex for waterproofing & repairs<br />
IFRI 25<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Terrace waterproofing<br />
with heat resistant<br />
coating<br />
WaTERPRooFING CUM HEaT REDUCTIoN<br />
SySTEM<br />
Dr. Fixit Newcoat,<br />
Dr. Fixit<br />
heatShielD<br />
Methodology<br />
Surface Preparation<br />
The surface shall be cleaned thoroughly<br />
of all contaminants like dust, traces of<br />
curing compound, oil and grease. All surface<br />
imperfections, protrusions, structurally<br />
unsound and loose concrete must be removed<br />
and repaired with polymer modified mortar<br />
using Dr. Fixit Pidicrete URP.<br />
Provide angle fillets in cement mortar admixed<br />
with Dr. Fixit Pidicrete URP, of 50 mm x 50<br />
mm all along the junction of the parapet wall<br />
& the roof slab.<br />
Priming<br />
Apply Dr. Fixit Primeseal to a clean, smooth<br />
surface by brush or roller. Allow the primer<br />
to dry prior to the application of Dr. Fixit<br />
Newcoat. During application of Dr. Fixit<br />
Primeseal always maintain the saturated<br />
surface dry condition.<br />
Application<br />
Apply 1st coat of Dr. Fixit Newcoat and while<br />
it is still wet lay an open woven 2.5 x 2.5<br />
mm glass fibre mesh and allow it to soak<br />
completely.<br />
Immediately apply 2nd coat of Dr. Fixit<br />
Newcoat to embed the mesh in coating. Allow<br />
it to dry completely. Ensure that the coating<br />
is extended up to 300 mm on vertical walls<br />
covering the angle fillets completely.<br />
System Life<br />
Expectancy<br />
of 10 years<br />
Apply 3rd coat of Dr. Fixit Newcoat. Allow it<br />
to dr.y completely. Ensure that the coating<br />
is extended up to 300 mm on vertical walls<br />
covering the angle fillets completely.<br />
Apply 1st coat of Dr. Fixit Heatshield over<br />
the Dr. Fixit Newcoat and allow it to dr.y<br />
for 6-8 hrs<br />
Apply 2nd coat of Dr. Fixit Heatshield and allow<br />
it to dry.<br />
Dr. Fixit Newcoat Dr. Fixit Heatshield Dr. Fixit Pidicrete URP<br />
Heavy duty reinforced acrylic waterproofing<br />
coating<br />
Energy saving, heat resistant coating and waterproofing<br />
coating system<br />
8<br />
7<br />
6<br />
5<br />
4<br />
1 Concrete Slab<br />
2 Screed<br />
3 Angle Fillet<br />
4 Dr. Fixit Primeseal<br />
5 Dr. Fixit Newcoat - 1st coat<br />
6 Open woven glass fibre mesh<br />
7 Dr. Fixit Newcoat - 2nd & 3rd coat<br />
8 Dr. Fixit Heatshield (2 coats)<br />
9 Drip mould<br />
Heat resistant exterior coating SBR Latex for waterproofing & repairs<br />
IFRI 10<br />
9<br />
3<br />
2<br />
1<br />
29