Terrace waterproofing<br />

with heat insulation<br />

WaTERPRooFING aND HEaT INSULaTIoN<br />

SySTEM FoR THE FLaT RooFS<br />

Dr. Fixit exteNSa,<br />

Dr. Fixit FoamShielD<br />

& Dr. Fixit<br />

Newcoat<br />

Surface Preparation<br />

The surface shall be cleaned thoroughly<br />

of all contaminants like dust, traces of<br />

curing compound, oil and grease. All surface<br />

imperfections, protrusions, structurally<br />

unsound and loose concrete must be removed<br />

and repaired with polymer modified mortar<br />

using Dr. Fixit Pidicrete URP.<br />

Priming<br />

Priming generally not required on concrete<br />

substrates for Dr. Fixit Extensa.<br />

Application<br />

Spray apply liquid, protective waterproofing<br />

coating, Dr. Fixit Extensa, over the entire slab<br />

area with a designated pump. It will act as a<br />

tough and excellent waterproofing barrier for<br />

the subsequent coat of Dr. Fixit Foamshield<br />

Then spray apply polyurethane foam Dr.<br />

Fixit Foamshield, of average thickness 35<br />

to 45 mm with a density of 50 kg per cu.m.<br />

approximately. This will harden for subsequent<br />

application over it.<br />

Brush apply protective acrylic waterproofing<br />

coating, Dr. Fixit Newcoat, over the entire<br />

PU Foam spread area, at approximately 300<br />

microns DFT.<br />

System Life<br />

Expectancy<br />

of 25 years<br />

Loosely lay geotextile fabric of 120 gsm, with<br />

overlap of 30 cm., after Dr. Fixit Newcoat dries<br />

Fix ridges in panels (area larger than 10 sq.m.<br />

& slope of 1 in 100 or 1 in 80), using bitumen<br />

impregnated boards & cement sand mortar.<br />

Lay or cast screed of concrete in M 20 in slope<br />

in 1: 100. Average thickness of screed is 75 to<br />

100 mm.<br />

The ridges of bitumen impregnated boards or<br />

polyboard will act as construction joints. Using<br />

the grinding wheel, expose the joints and form<br />

grooves.<br />

Fix backing rod & apply elastomeric<br />

polysulphide sealant, Dr. Fixit Pidiseal PS 42P<br />

in all grooves of the construction joints in the<br />

concrete screed<br />

Fix angle fillets in concrete along the parapet,<br />

mechanical duct openings & pre-utility up<br />

stands.<br />

Apply a final coat of Dr. Fixit Newcoat of 300<br />

micron DFT over the concrete screed & angle<br />

fillets (50 mm height) as a sealer coat, up to<br />

the flashing.<br />

Dr. Fixit Extensa Dr. Fixit Newcoat Dr. Fixit Pidicrete URP<br />

Highly elastomeric and puncture resistant<br />

waterproofing coating<br />

Highly energy efficient, extremely lightweight, high end<br />

waterproofing and insulating system<br />

Heavy duty reinforced acrylic waterproofing<br />

coating<br />

9<br />

8<br />

1 Slab<br />

2 Dr. Fixit Extensa<br />

3 Dr. Fixit Foamshield<br />

4 Dr. Fixit Newcoat<br />

5 Geotextile<br />

6 Screed<br />

7 Angle Fillet<br />

8 Dr. Fixit Newcoat<br />

9 Drip mould<br />

SBR Latex for waterproofing & repairs<br />

IFRI 25<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Terrace waterproofing<br />

with heat resistant<br />

coating<br />

WaTERPRooFING CUM HEaT REDUCTIoN<br />

SySTEM<br />

Dr. Fixit Newcoat,<br />

Dr. Fixit<br />

heatShielD<br />

Methodology<br />

Surface Preparation<br />

The surface shall be cleaned thoroughly<br />

of all contaminants like dust, traces of<br />

curing compound, oil and grease. All surface<br />

imperfections, protrusions, structurally<br />

unsound and loose concrete must be removed<br />

and repaired with polymer modified mortar<br />

using Dr. Fixit Pidicrete URP.<br />

Provide angle fillets in cement mortar admixed<br />

with Dr. Fixit Pidicrete URP, of 50 mm x 50<br />

mm all along the junction of the parapet wall<br />

& the roof slab.<br />

Priming<br />

Apply Dr. Fixit Primeseal to a clean, smooth<br />

surface by brush or roller. Allow the primer<br />

to dry prior to the application of Dr. Fixit<br />

Newcoat. During application of Dr. Fixit<br />

Primeseal always maintain the saturated<br />

surface dry condition.<br />

Application<br />

Apply 1st coat of Dr. Fixit Newcoat and while<br />

it is still wet lay an open woven 2.5 x 2.5<br />

mm glass fibre mesh and allow it to soak<br />

completely.<br />

Immediately apply 2nd coat of Dr. Fixit<br />

Newcoat to embed the mesh in coating. Allow<br />

it to dry completely. Ensure that the coating<br />

is extended up to 300 mm on vertical walls<br />

covering the angle fillets completely.<br />

System Life<br />

Expectancy<br />

of 10 years<br />

Apply 3rd coat of Dr. Fixit Newcoat. Allow it<br />

to dr.y completely. Ensure that the coating<br />

is extended up to 300 mm on vertical walls<br />

covering the angle fillets completely.<br />

Apply 1st coat of Dr. Fixit Heatshield over<br />

the Dr. Fixit Newcoat and allow it to dr.y<br />

for 6-8 hrs<br />

Apply 2nd coat of Dr. Fixit Heatshield and allow<br />

it to dry.<br />

Dr. Fixit Newcoat Dr. Fixit Heatshield Dr. Fixit Pidicrete URP<br />

Heavy duty reinforced acrylic waterproofing<br />

coating<br />

Energy saving, heat resistant coating and waterproofing<br />

coating system<br />

8<br />

7<br />

6<br />

5<br />

4<br />

1 Concrete Slab<br />

2 Screed<br />

3 Angle Fillet<br />

4 Dr. Fixit Primeseal<br />

5 Dr. Fixit Newcoat - 1st coat<br />

6 Open woven glass fibre mesh<br />

7 Dr. Fixit Newcoat - 2nd & 3rd coat<br />

8 Dr. Fixit Heatshield (2 coats)<br />

9 Drip mould<br />

Heat resistant exterior coating SBR Latex for waterproofing & repairs<br />

IFRI 10<br />

9<br />

3<br />

2<br />

1<br />

29