Exposed flat roofs<br />
ExPoSED WaTERPRooFING SySTEM FoR<br />
THE FLaT RooFS<br />
Dr. Fixit torchShielD<br />
aP 4160 & am 4160<br />
Methodology<br />
Surface Preparation<br />
Thorough surface preparation is a must over<br />
the entire roof area<br />
Screed in concrete in M 20 modified with<br />
Dr. Fixit Pidiproof LW+ must be laid with<br />
a slope of 1 in 100, with at least 50 mm<br />
thickness at the drain outlet. Screed must be<br />
cured and dried completely.<br />
Priming<br />
Prime the surface with Dr. Fixit Torchshield<br />
Primer. Allow it to dry for 8 to 10 hrs.<br />
Application<br />
Start the application of a first layer of Dr. Fixit<br />
Torchshield AP 4160 (plain finish APP based)<br />
The application must start from the outlet,<br />
going towards the centre of the roof area.<br />
System Life<br />
Expectancy<br />
of 10 years<br />
This 1st layer is laid, up to over the angle<br />
fillet only.<br />
The 2nd layer of Dr. Fixit Torchshield AM 4160<br />
must laid in a perpendicular direction to the<br />
1st membrane, starting from 150 to 200 mm<br />
on the parapet wall, downward and covering<br />
the angle fillet. This is a mineral finished APP<br />
based membrane 4 mm thick.<br />
The surface area of Dr. Fixit Torchshield AM<br />
4160 has mineral slate on the surface and it<br />
can be left exposed it should be terminated at<br />
a height of 20 cm.<br />
The top edge of the membrane will be finished<br />
with 2 mm thick aluminium flashing pointed<br />
with Dr. Fixit Pidiseal PS 42P.<br />
Dr. Fixit Torchshield Dr. Fixit Pidiproof LW+ Dr. Fixit Pidiseal PS 42P<br />
aPP / SBS modified bitumen based membrane Integral liquid waterproofing compound for<br />
plaster and concrete<br />
Reliable lightweight waterproofing membrane system<br />
with UV resistant mineral finish<br />
5<br />
4<br />
1<br />
1 Slab<br />
2 Screed<br />
3 Angle Fillet<br />
3 Dr. Fixit Torchshield Primer<br />
4 Dr. Fixit Torchshield AP 4160<br />
5 Dr. Fixit Torchshield AM 4160<br />
6 Aluminium Flashing<br />
7 Dr. Fixit Pidiseal PS 42P<br />
Two-part polysulphide sealant<br />
EFR 10<br />
8<br />
7<br />
6<br />
3<br />
2<br />
Flat roofs with brickbat<br />
coba<br />
WaTERPRooFING SySTEM UNDER<br />
CoNvENTIoNaL BRICkBaT CoBa<br />
Dr. Fixit SolySeal<br />
Methodology<br />
Surface Preparation<br />
The surface shall be cleaned thoroughly<br />
of all contaminants like dust, traces of<br />
curing compound, oil and grease. All surface<br />
imperfections, protrusions, structurally<br />
unsound and loose concrete must be removed<br />
and repaired with polymer modified mortar<br />
using Dr. Fixit Pidicrete URP.<br />
Make angle fillets all around the periphery<br />
of the terrace with a cement – sand mortar<br />
admixed with Dr. Fixit Pidicrete URP.<br />
Priming<br />
Apply Dr. Fixit Solyseal diluted with water in<br />
1:1 proportion as primer to clean, smooth and<br />
surface by brush or roller in saturated surface<br />
dry condition and allow it to dry completely.<br />
System Life<br />
Expectancy<br />
of 5 years<br />
Highly elastomeric waterproofing<br />
system below brickbat coba<br />
Application<br />
Apply the 1st coat of Dr. Fixit Solyseal without<br />
any dilution and allow it to dry completely.<br />
Start the 2nd coat of Dr. Fixit Solyseal, with a<br />
roller or a rubber squeegee & allow it to dry.<br />
Place loosely laid geotextile fabric of 300<br />
to 500 gsm over the Dr. Fixit Solyseal for<br />
protection.<br />
Carefully lay brickbat coba to provide slope<br />
1:100 for effective drainage of water.<br />
Dr. Fixit Solyseal Dr. Fixit Pidicrete URP<br />
1 Slab<br />
2 Primer<br />
3 Angle Fillet<br />
4 Dr. Fixit Solyseal (2 coats)<br />
5 Geotextile<br />
6 Brickbat coba<br />
7 Drip Mould<br />
Polymer modified elastomeric bituminous coating SBR Latex for waterproofing & repairs<br />
1<br />
IFR 5<br />
(BBC)<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
25