External walls<br />

ExTERNaL WaLLS WaTERPRooF CoaTING<br />

Dr. Fixit raiNcoat with<br />

Dr. Fixit PrimeSeal<br />

Surface Preparation<br />

Ensure complete surface preparation prior to<br />

application. Remove all loose dirt, dust and oil,<br />

etc., from the surface.<br />

Check for all surface cracks and clean them to<br />

remove all loose laitance & wash with water<br />

Apply crack-filler, Dr. Fixit Crack-X Paste/<br />

Shrinkfree depending upon the width of<br />

crack (use paste for cracks up to 3-5 mm and<br />

Shrinkfree for cracks up to 10 mm) with a<br />

putty blade properly by pressing the material<br />

in cracks.<br />

The loose and loose plaster shall be removed<br />

and re-done using polymer modified mortar<br />

modified with Dr. Fixit Pidicrete URP.<br />

System Life<br />

Expectancy<br />

of 5 years<br />

Priming<br />

Prime the surface with Dr. Fixit Primeseal<br />

diluted 2:1 with water maintaining the<br />

saturated surface dry condition. Allow to dry<br />

completely.<br />

Application<br />

Apply 1st coat of Dr. Fixit Raincoat without<br />

dilution maintaining the spreading rate. Allow<br />

to dry for 6-8 hrs<br />

Apply 2nd coat in direction perpendicular to 1st coat ensuring complete covering of the area.<br />

Dr. Fixit Raincoat Dr. Fixit Pidicrete URP Dr. Fixit Primeseal Dr. Fixit Crack-X Shrinkfree<br />

acrylic Elastomeric Exterior<br />

Waterproof Coating<br />

SBR Latex for waterproofing &<br />

repairs<br />

High performance elastomeric waterproof coating<br />

for leak-free exterior walls<br />

Efflorescence resistant penetrative<br />

primer<br />

1 Spalled plaster<br />

2 Exposed brick masonry<br />

3 Plaster reinstated using PMM<br />

mixed with Dr. Fixit Pidicrete URP<br />

4 Column<br />

5 Separation joint filled using PMM<br />

Dr. Fixit Pidicrete URP<br />

6 Plaster cracks filled with<br />

Dr. Fixit Crack-X Shrinkfreee<br />

7 Primer coat of Dr. Fixit Primeseal<br />

8 Separation joint RCC-Masonry<br />

9 2 coats of Dr. Fixit Raincoat<br />

10 Beam<br />

100 % shrinkfree crack filler<br />

EWWP 5<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Manholes<br />

MaNHoLE WaTERPRooFING<br />

Dr. Fixit SamShielD xl<br />

1500 & Dr. Fixit coal<br />

tar ePoxy<br />

Methodology<br />

exterNAl surfAce of mANhole<br />

Surface Preparation<br />

The surface shall be cleaned thoroughly<br />

of all contaminants like dust, traces of<br />

curing compound, oil and grease. All surface<br />

imperfections, protrusions, structurally<br />

unsound and loose concrete must be removed<br />

and repaired with polymer modified mortar<br />

using Dr. Fixit Pidicrete URP.<br />

Priming<br />

Apply Dr. Fixit Torchshield Primer to a clean,<br />

smooth and dry surface by brush or roller.<br />

Allow the primer to dry prior to the application<br />

of the membrane.<br />

Application<br />

It is very important to cut the membrane in<br />

specific size as per the manhole design from<br />

external side before execution of job.<br />

Apply Dr. Fixit Samshield XL 1500 self<br />

adhesive SBS modified membrane by removing<br />

the silicon releasing paper on the primed<br />

surface.<br />

Dr. Fixit Samshield XL 1500 membrane<br />

shall then be applied on top of the exposed<br />

tape overlapping by 100 mm. The subsequent<br />

membrane will then be overlapped with other<br />

100 mm of tape.<br />

System Life<br />

Expectancy<br />

of 10 years<br />

Protection to buried concrete in adverse environment<br />

4 mm bituminous protection board / geotextile<br />

membrane shall be placed over it for<br />

protection against damage in case the land<br />

filling contains heavy boulders etc. which may<br />

damage the membrane.<br />

Dr. Fixit Samshield XL 1500 to be used for<br />

external surface & Dr. Fixit Coal Tar Epoxy for<br />

internal surface. Alternatively Dr. Fixit Coal<br />

Tar Epoxy can be used for both external &<br />

internal surfaces.<br />

INterNAl surfAce of mANhole<br />

Surface Preparation<br />

The surface shall be cleaned thoroughly<br />

of all contaminants like dust, traces of<br />

curing compound, oil and grease. All surface<br />

imperfections, protrusions, structurally<br />

unsound and loose concrete must be removed<br />

and repaired with polymer modified mortar<br />

using Dr. Fixit Pidicrete URP.<br />

MHWP 10<br />

Priming<br />

Since Dr. Fixit Coal Tar Epoxy is self priming<br />

there is no need for special primer.<br />

Application<br />

Apply 1st coat of Dr. Fixit Coal Tar Epoxy and<br />

allow it to dry completely for 12 to 15 hrs<br />

depending upon the site conditions.<br />

Apply 2nd coat of Dr. Fixit Coal Tar Epoxy and<br />

allow it to dry completely.<br />

The manhole shall be made operational after<br />

4-7 days after full curing of Dr. Fixit Coal Tar<br />

Epoxy internally.<br />

Dr. Fixit Samshield Dr. Fixit Coal Tar Epoxy Dr. Fixit Pidicrete URP<br />

Self adhesive bituminous membrane Two-component coal tar epoxy coating for<br />

concrete surface<br />

SBR Latex for waterproofing & repairs<br />

37