Connecting terminal plates<br />

incl. cover<br />

Connection module, shock-protected<br />

60mm distance between busbar centres<br />

3-pole, 690V ~<br />

16mm 2 (with spring terminal)<br />

50, 120mm 2<br />

185, 300mm 2 , 10 x 32 x 1<br />

not for busbar widths 12 and 15mm<br />

Conductors used Current carrying Terminal Busbars Part-no.<br />

capacity space W x H<br />

of contacts* W x H<br />

1.5 –16mm2 Cu, sol(r), s(r), 80A … x 5 – 10 01 563<br />

f, f +AE** TT, TTT<br />

6 – 50 (70)mm2 Cu,s(r), f, 300A 10 x 15 … x 5 – 10 01 240<br />

f + AE**, fl. Cu 6 x 9 x 0.8 TT, TTT<br />

35 –120mm2 Cu,s(r), f, f +AE**, Al***, sol(s) 440A 15 x 15 … x 5 – 10 01 243<br />

fl. Cu 6/10 x 13/15.5 x 0.5/0.8 TT, TTT<br />

95 –185mm2 Cu, Al***, 460A 20 x5 – 30 x 1 0 01 199<br />

s(r), s(s), f TT, TTT<br />

35–150 mm2 Cu, s(r), f, f +AE** 480A 12x5<br />

12x 10<br />

01 165<br />

150 – 300mm2 Cu, Al***, 560A 20 x5 – 30 x 1 0 01 754<br />

s(r), s(s), f TT, TTT<br />

fl. Cu 3 x 20 x 1 800A 32 x 25 20 x5 – 30 x 1 0 01 753<br />

up to 10 x 32 x 1 TT, TTT<br />

Connection set, 3-pole and 4-pole<br />

without cover<br />

300mm 2 , 10 x 32 x 1<br />

1-pole, 690V~<br />

60mm distance between busbar centres<br />

busbars 20 x 5–30 x 10<br />

double-T and triple-T section<br />

Conductors used Current carrying Terminal Busbars Part no.<br />

capacity space W x H<br />

of contacts* W x H<br />

120–300mm2 Cu, Al***, 560A 20 x 5– 30 x 10 01 537<br />

s(r), s(s), f TT, TTT 01 147<br />

fl. Cu 3 x 20 x 1 800A 32 x 25 20 x 5– 30 x 10 01 538<br />

up to 10 x 32 x 1 TT, TTT 01 162<br />

* The specified ratings reflect the thermal capacity of the terminals under optimal conditions<br />

(with the largest connectable conductors).<br />

The allocation of conductor cross-sections and current carrying capacities by national or<br />

international specifications does not affect the terminal’s thermal capacity.<br />

** Reducing the maximum conductor cross-sections may be required.<br />

*** not maintenance-free if aluminium conductors are used (see page 8/ 2).<br />

Explanation of abbreviations on page 8/ 2.<br />

Additional terminal space details on page 9/8.<br />