For conventional cabling, Wöhner offers a comprehensive<br />

range of panel components suitable for either plate or<br />

DIN-rail mounting. Fuses and the associated connection<br />

technology meet the highest safety and quality requirements<br />

set by international standards.<br />

CUSTO®EasyBase<br />

Space-saving fuse base D01 and D02 for mounting in the<br />

45mm standard field section. The large dual function<br />

terminal allows direct convenient connection for all conductor<br />

types. The integrated cover and extensive shock<br />

protection provide a high degree of safety during installation,<br />

operation and maintenance.<br />

TRITON®<br />

Fully shock-protected fuse base according to DIN<br />

EN 50274 / BGV A3. For clip-on attachment or screwmounting<br />

onto mounting rails according to DIN<br />

EN 60715. 1- and 3-pole models for D01, D02, DII and DIII.<br />

AMBUS®EasySwitch<br />

The mounting for the cylindrical fuses is for currents up to<br />

32A (10 x 38) and only 18 mm wide. With a short-circuit<br />

rating up to 100 kA and a shock protection according to<br />

VDE 0106, the circuits up to 690V can be protected up to<br />

80A (22 x 58, at 400V up to 125A). Variants with neutral<br />

conductor, LED, for semi-conductor protection, DC applications<br />

up to 1000V and pilot switch.<br />

AMBUS®EasySwitch Class CC<br />

For class CC fuses according to UL 248-4 up to 30A.<br />

According to American standards with a short-circuit<br />

rating up to 200kA. Variants with LED for fuse moni -<br />

toring.<br />

AMBUS®J-Carrier<br />

QUADRON®J-Carrier<br />

For Class J fuses in compliance with UL 248-8. Compliant<br />

with American standard for fuses with a short-circuit<br />

capacity of up to 200kA. The design also protects from<br />

contact as required in many applications.<br />

NH Fuse Bases and Neutral Conductors<br />

Single-pole and three-pole NH fuse bases can be used<br />

to protect circuits up to 630A/690V. Matching disconnectable<br />

neutral conductor with an optimised design are<br />

also available.<br />

CUSTO®EasyBase<br />

Integrated cover<br />

Dual-function terminal<br />

Extensive shock protection<br />

AMBUS® J-Carrier<br />

For class J fuses<br />

with cylindrical design<br />

according to UL 248-8<br />

Models up to 60A<br />