5.1. Safe shut down of the high voltage before access to live parts<br />

In order to ensure the safety it is mandatory to follow the steps 1-5 mentioned below<br />

before and during a release of access to live electrical components. This has also to be<br />

ensured by technical means:<br />

1. Switch off high voltage via CAN bus command<br />

2. Wait until generator sets the bit „High voltage is off safely“. This should occur after<br />

10 to 60 seconds. For safety reasons this duration should be observed over<br />

life time to recognize changes of the electical capacity of the installation.<br />

3. Switch off 24V supply (safe)<br />

4. Take measures to secure 24V supply against reconnecting<br />

5. Ground active parts with earth stick<br />

6. Repair and Maintenance<br />

The terms for the normal use as specified above apply also during repair and maintenance<br />

situations. Furthermore the operating instructions of the surrounding installation<br />

have to be observed.<br />

This HV generator does not contain any user repairable parts. It can only be repaired<br />

by the manufacturer.<br />

If the generator has to be uninstalled for repair the following order of disconnecting the<br />

Signals is recommended:<br />

1. Check if parts carrying HV during normal operation are grounded<br />

2. Remove M12 connector<br />

3. Unplug HV connector<br />

4. Remove ground<br />

WARNING<br />

If a HV generator is uninstalled avoid to touch metallic parts,<br />

that are active during operation without grounding them with an<br />

earth stick BEFORE the ground connector of the HV generator<br />

is disconnected !<br />

Observe this in particular when a generator is defect !<br />

Any warranty is void if the HV generator is opened and/or<br />

modified, if parts were replaced by others than the original<br />

ones.<br />

<strong>Operating</strong> Instructions 810364_BAL_EN120302 Stand 02.03.2012 Seite 13 von 25