3. Intended Use<br />

This Product is dedicated for the use in stationary installations which comply with the<br />

safety requirements of at least one of this harmonized standards:<br />

EN 50176:2009,<br />

EN 50177:2009,<br />

EN 50223:2010 or<br />

EN 50348 :2010<br />

This high voltage generator is classified as category 3G and/or 3D equipment for use in<br />

Zone 2 and/or Zone 22 in potentially explosive atmospheres.<br />

Permitted is only the use in potentially explosive atmospheres which are caused by the<br />

spray cloud of the processed coating material itself.<br />

WARNING<br />

any other or extended use is strictly prohibited and lead to a potentially<br />

hazardous situation which could result in death or injury<br />

This device must not be used stand-alone. It has to be fully installed in stationary<br />

equipment that complies in total with the product standards mentioned above.<br />

3.1.Further Requirements for the Stationary Equipment<br />

This HV-generator must be used only in electrostatic units within a temperature<br />

range of 15 °C to 40 °C and a relative humidity between 10%<br />

and 70%.(non-condensing)<br />

This HV-generator is intended for incorporation in a given fixed<br />

installation in industrial environments. There may be difficulties to ensure<br />

electromagnetic compability (EMC) in other environments.<br />

To avoid potentially hazardous situations it is necessary to do a risk analysis<br />

of the installation in total. Particularly with regard to safety categories<br />

and/or performance levels stated in the relevant product standards this is<br />

mandatory*<br />

* Since the spray system is connected via a high voltage cable to the high voltage generator,<br />

a performance level cannot be ensured by the high voltage generator alone. For<br />

this, a second high voltage cable from the spray system returned to a redundant measurement<br />

path in the high voltage generator would be necessary.<br />

<strong>Operating</strong> Instructions 810364_BAL_EN120302 Stand 02.03.2012 Seite 5 von 25