7. Functional Description<br />

7.1. General<br />

The high voltage generator is built as a compact design. The control, power amplifier,<br />

the transformer and the HV multiplier are combined in one device. Supply Voltage is<br />

24 V DC. The built-in microcontroller provides a very accurate and fast control of the<br />

HV output.<br />

7.2. Safety<br />

The voltage (U) at the HV connector is measured permanently even after switching off<br />

the high voltage. With a given capacity (C) one can calculate the discharging energy<br />

(E) that remains in the spraying system and the high voltage supply system:<br />

E=1/2C* U 2<br />

E: remaining discharging energy after switch off in Joule<br />

C: total capacity of the whole HV supply system in Farad<br />

U: Voltage level in Volt<br />

Factory preset for the calculation by the HV generator is 3nF. This value can be<br />

changed via CAN bus to the actual capacity of the installation (not yet implemented).<br />

Based on the limit of 0.24mJ (EN 50176,50177,50223) for the discharge energy to be<br />

safe the hv generator sets the bit “high voltage is off safely” in the status word if E is<br />

below this limit. Otherwise the bit is reset. For 3nF and 0.24mJ the voltage limit is about<br />

400V.<br />

WARNING<br />

If a Generator has to be removed for repair –<br />

especially after the occurence of failures of selftests –<br />

Observe Section 6 of this manual.<br />

<strong>Operating</strong> Instructions 810364_BAL_EN120302 Stand 02.03.2012 Seite 14 von 25