7.3. Block Diagram<br />

24 VDC<br />

CANopen<br />

Power<br />

Stagel<br />

7.4. Specification<br />

Micro<br />

Controller<br />

Transformer<br />

I-Measurement<br />

U-Measurement<br />

HV Multiplier Protection HS-<br />

Resistor Ausgang<br />

Measurement<br />

Resistor<br />

Supply Voltage 24 V DC max. 2A<br />

Output Voltage 10-100 kV negative<br />

Output Current 300uA<br />

Max. installation capacity 2 nF<br />

Environment +15°C bis 40°C max. 70% rel . humidity non condensing.<br />

Storage Temperature -20°C - +70°C<br />

Dimensions see 4.3.<br />

Weight Max 3,5 kg<br />

Protection IP 65<br />

HV Connector Anode tube with 4mm hv connector<br />

Bus Interface Based on CAN Open<br />

Operation Modes Constant U (Voltage) and Constant I (current)<br />

<strong>Operating</strong> Instructions 810364_BAL_EN120302 Stand 02.03.2012 Seite 15 von 25