7.3. Block Diagram<br />
24 VDC<br />
CANopen<br />
Power<br />
Stagel<br />
7.4. Specification<br />
Micro<br />
Controller<br />
Transformer<br />
I-Measurement<br />
U-Measurement<br />
HV Multiplier Protection HS-<br />
Resistor Ausgang<br />
Measurement<br />
Resistor<br />
Supply Voltage 24 V DC max. 2A<br />
Output Voltage 10-100 kV negative<br />
Output Current 300uA<br />
Max. installation capacity 2 nF<br />
Environment +15°C bis 40°C max. 70% rel . humidity non condensing.<br />
Storage Temperature -20°C - +70°C<br />
Dimensions see 4.3.<br />
Weight Max 3,5 kg<br />
Protection IP 65<br />
HV Connector Anode tube with 4mm hv connector<br />
Bus Interface Based on CAN Open<br />
Operation Modes Constant U (Voltage) and Constant I (current)<br />
<strong>Operating</strong> Instructions 810364_BAL_EN120302 Stand 02.03.2012 Seite 15 von 25