Cleaninu Tank Concentration (om)<br />
Above tank<br />
Inside barrel berm - top<br />
of barrel<br />
Outside berm<br />
Backhoe<br />
Some final clean up in <strong>the</strong> sump area was also conducted. The employees<br />
wore Level C with a full face respirator for this activity. The OVA<br />
readings were as follows:<br />
Cl eanina Sumo Concentration (ooml<br />
Outside sump area<br />
Sump trap inside<br />
During <strong>the</strong> day, it became necessary for an employee to enter <strong>the</strong> open tank<br />
to shovel <strong>the</strong> residual sludge into <strong>the</strong> backhoe bucket. Confined Space<br />
Entry procedures were utilized for this activity. The employee entering<br />
<strong>the</strong> tank wore an airline respirator with an escape bottle, saranex suit,<br />
rubber boots, chemical-resistant gloves (inner and outer), and a safety<br />
harness with a safety line attached. A stand-by observer was equipped with<br />
a SCBA, saranex suit, rubber boots, and chemical-resistant gloves (inner<br />
and outer). The OVA was re-cal i brated and <strong>the</strong> background established at<br />
0.8 ppm. The OVA readings obtained were as follows:<br />
Tank Entry Concentration (o~rn)<br />
Above tank<br />
Outside berm<br />
Backhoe<br />
After lunch, cleaning inside <strong>the</strong> tank continued with <strong>the</strong> same level of<br />
protection as noted above. Upon completion of <strong>the</strong> sludge removal, <strong>the</strong><br />
inside of <strong>the</strong> tank was steam-cleaned. The OVA was re-calibrated and <strong>the</strong><br />
background established at 2.0 ppm. The OVA readings were as follows: