Drawings - Peak Engineering and Construction Ltd
Drawings - Peak Engineering and Construction Ltd
Drawings - Peak Engineering and Construction Ltd
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
A<br />
B<br />
C<br />
D<br />
1 2 3 4 5 6<br />
FLOC TANK No. 3<br />
FLOC TANK No. 1<br />
RAPID MIXING<br />
CHAMBER<br />
CHEMICAL PIPING DEMOLITION<br />
1:50<br />
CHAMBER<br />
REMOVE EXISTING 65 PVC<br />
POLYELECTROLYTES PIPE<br />
EXCEPT FOR PORTION IN<br />
SODA ASH<br />
RETENTION<br />
CHAMBER<br />
SODA ASH<br />
RETENTION<br />
CHAMBER<br />
JANITOR ROOM<br />
EXISTING 40 PVC CHLORINE<br />
CHEMICAL<br />
STORAGE<br />
EXISTING WALL BETWEEN SODA<br />
ASH RETENTION CHAMBER AND<br />
JANITOR ROOM. PROVIDE PVC<br />
CAP ON PIPE ON JANITOR ROOM<br />
SIDE OF WALL ONLY. FILL PIPE<br />
COMPLETELY WITH GROUT FLUSH<br />
WITH SODA ASH RETENTION<br />
CHAMBER WALL<br />
REMOVE EXISTING 65 PVC<br />
SODIUM CARBONATE PIPE<br />
EXCEPT FOR PORTION IN<br />
EXISTING WALL BETWEEN SODA<br />
ASH RETENTION CHAMBER AND<br />
JANITOR ROOM. PROVIDE PVC<br />
CAP ON PIPE ON JANITOR ROOM<br />
SIDE OF WALL ONLY. FILL PIPE<br />
COMPLETELY WITH GROUT FLUSH<br />
WITH SODA ASH RETENTION<br />
CHAMBER WALL<br />
EXISTING CONCRETE BLOCK WALL<br />
COVERING CONCRETE TANK WALL<br />
BETWEEN SODA ASH RETENTION<br />
CHAMBER AND JANITOR ROOM<br />
1<br />
PHOTO<br />
2<br />
PHOTO<br />
SODA ASH MIXING CHAMBER<br />
REMOVE EXISTING 65 PVC<br />
SODIUM CARBONATE PIPING<br />
REMOVE EXISTING 65 PVC<br />
PHOTOGRAPH (JANITOR ROOM)<br />
1 NTS<br />
PROVIDE PVC CAP ON PIPE ON ONE SIDE OF EACH WALL ONLY.<br />
CUT PIPE FLUSH WITH OTHER SIDE OF WALL WHEN REMOVING<br />
PIPE SECTIONS. FILL PIPE WITHIN WALL COMPLETELY WITH<br />
NON-SHRINK, NON-FERROUS GROUT FLUSH WITH OTHER SIDE<br />
OF WALL. REFER TO DETAIL ON THIS DRAWING FOR NEW CHEMICAL<br />
PIPING. ALL REPAIRS TO BE WATER TIGHT<br />
POLYELECTROLYTES PIPING<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
EXISTING 40 PVC CHLORINE<br />
EXISTING CONCRETE<br />
TANK WALL<br />
EXISTING CONCRETE<br />
BLOCK WALL<br />
EXISTING 65 PVC POLYELECTROLYTES<br />
PIPING TERMINATES AT THIS POINT<br />
REMOVE EXISTING 65 PVC<br />
SODIUM CARBONATE PIPE<br />
BACK TO SODA ASH ROOM<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
EXISTING 40 PVC CHLORINE EXISTING 40 PVC CHLORINE<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
REFER TO PHOTOGRAPH 2<br />
FOR CONTINUATION AND<br />
PIPE DEMOLITION DETAILS<br />
THROUGH THIS WALL<br />
EXISTING CONCRETE<br />
BLOCK WALL<br />
1 DETAIL<br />
NTS<br />
000-D-2001<br />
EXISTING CONCRETE<br />
TANK WALL<br />
EXISTING CONCRETE<br />
BLOCK WALL<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
REFER TO PHOTOGRAPH 1<br />
FOR CONTINUATION<br />
REMOVE EXISTING 65 PVC<br />
POLYELECTROLYTES PIPE<br />
AND 65 PVC SODIUM<br />
CARBONATE PIPE ON<br />
BOTH SIDES OF WALL<br />
SEPARATING JANITOR ROOM<br />
AND CHEMICAL STORAGE AS<br />
SHOWN. CUT PIPES FLUSH<br />
WITH WALL ON BOTH SIDES<br />
OF WALL. PIPES TO REMAIN<br />
IN WALL AND WILL BE USED<br />
AS SLEEVES FOR 2 NEW<br />
40-LS-PVC PIPES. REFER TO<br />
"NEW CHEMICAL PIPING" ON<br />
THIS DRAWING FOR ADDITIONAL<br />
DETAILS<br />
EXISTING CONCRETE BLOCK<br />
WALL BETWEEN JANITOR ROOM<br />
AND CHEMICAL STORAGE<br />
2 NTS<br />
FLOC TANK No. 3<br />
FLOC TANK No. 1<br />
1:50<br />
CHAMBER<br />
SODA ASH<br />
RETENTION<br />
CHAMBER<br />
FL EL 293.450<br />
RAPID MIXING<br />
CHAMBER<br />
SODA ASH<br />
RETENTION<br />
CHAMBER<br />
FL EL 293.450<br />
JANITOR ROOM<br />
CHEMICAL<br />
STORAGE<br />
FOR CONTINUATION<br />
1<br />
PHOTO<br />
2<br />
PHOTO<br />
50-CDS-PVC PIPES FROM CO2 PANEL.<br />
REFER TO DWG 000-D-2001<br />
TOC<br />
EL 297.850<br />
NEW CHEMICAL PIPING<br />
PHOTOGRAPH (CHEMICAL STORAGE)<br />
2<br />
000-D-5001<br />
REMOVE EXISTING 65 PVC<br />
SODIUM CARBONATE PIPE<br />
BACK TO SODA ASH ROOM.<br />
RUN 2 NEW 40-LS-PVC PIPES<br />
IN EXISTING PIPE TRAY ALONG<br />
SAME ROUTE AS REMOVED<br />
SODIUM CARBONATE PIPE<br />
NOTES:<br />
50-CDS-PVC<br />
RETENTION CHAMBER<br />
SODA ASH MIXING CHAMBER<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
EXISTING 40 PVC CHLORINE<br />
EXISTING 20 PVC<br />
ALUMINUM SULPHATE<br />
DIMENSIONS ARE APPROXIMATE.<br />
TERMINATE VERTICAL PIPE 500<br />
ABOVE BOTTOM OF SODA ASH<br />
4<br />
000-D-5001<br />
FL EL 293.450<br />
PROVIDE 40 NPT PVC TEE WITH PLUG.<br />
TERMINATE VERTICAL PIPE 1000 ABOVE<br />
SODA ASH MIXING CHAMBER FLOOR<br />
4<br />
000-D-5001<br />
50-CDS-PVC<br />
TERMINATE VERTICAL PIPE 500<br />
ABOVE BOTTOM OF SODA ASH<br />
RETENTION CHAMBER<br />
40-LS-PVC<br />
4<br />
000-D-5001<br />
2 REUSE EXISTING PIPE SLEEVES FROM<br />
SODIUM CARBONATE AND POLYELECTROLYTE<br />
000-D-5001PIPE<br />
REMOVAL DONE UNDER DEMOLITION ON<br />
THIS DRAWING<br />
40-LS-PVC FROM LIME ROOM (2 PIPES).<br />
RUN PIPES IN EXISTING PIPE TRAY<br />
ALONG SAME ROUTE AS REMOVED<br />
SODIUM CARBONATE PIPE. REFER TO<br />
DWG 000-D-2001 FOR CONTINUATION<br />
EXISTING 40 PVC CHLORINE<br />
1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS TO FAMILIARIZE<br />
THEMSELVES WITH THE SCOPE OF WORK PRIOR TO PROCEEDING.<br />
SOME PIPING AND EQUIPMENT HAS BEEN OMITTED, FOR CLARITY.<br />
2. EXISTING BACKGROUND TAKEN FROM TOTTEN SIMS HUBICKI ASSOCIATES<br />
IN ASSOCIATION WITH RYSCO ENGINEERING CORPORATION. PROJECT<br />
52-6630, DRAWING M3, AS CONSTRUCTED SEPT. 91. EXISTING BACKGROUND<br />
HAS BEEN MODIFIED BY CH2M HILL TO SUIT THIS PROJECT. ALL BACKGROUND<br />
DATE<br />
PROJ<br />
SHEET<br />
VERIFY SCALE<br />
FILENAME: 000-D-2007_424251.dgn PLOT DATE: 2012\07\26 PLOT TIME: 8:25:55 AM<br />
DISTRICT M UNICIPALITY<br />
DWG<br />
OF M USKOKA<br />
FAIRYVIEW W ATER TREATMENT PLANT<br />
PROCESS MECHANICAL<br />
MB<br />
JPN<br />
ISSUED FOR TENDER<br />
07/2012<br />
0<br />
PHASE I UPGRADES<br />
BAR IS 25mm ON<br />
APVD<br />
BY<br />
REVISION<br />
DATE<br />
NO.<br />
CONTRACT 12-432-253<br />
PIPING MODIFICATIONS (2)<br />
ORIGINAL DRAWING.<br />
0 25 MM<br />
APVD<br />
CHK<br />
DSGN DR<br />
14of62<br />
ET JPN<br />
JPN RC<br />
2012/07/27<br />
424251<br />
000-D-2007<br />
CH2M HILL 2012. ALL RIGHTS RESERVED.<br />
c<br />
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF<br />
CH2M HILL AND IS NOT TO BE USED, IN W HOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE W RITTEN AUTHORIZATION OF CH2MHILL.<br />
REUSE OF DOCUMENTS:<br />
ISSUED FOR TENDER