02.06.2013 Views

Drawings - Peak Engineering and Construction Ltd

Drawings - Peak Engineering and Construction Ltd

Drawings - Peak Engineering and Construction Ltd

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A<br />

B<br />

C<br />

D<br />

1 2 3 4 5 6<br />

2000<br />

pH PROBE CABLE<br />

SCH 40 PVC PIPE<br />

TO SUIT Ph PROBE<br />

SST BOLT, NUT, AND<br />

LOCK WASHER<br />

SCH 40 PVC PIPE<br />

GUIDE TO SUIT<br />

SST PIPE CLAMP WITH<br />

SST BOLTS, NUTS, AND<br />

LOCK WASHERS,<br />

TYPICAL<br />

1 DETAIL<br />

NTS<br />

000-D-2003<br />

300<br />

PLAN<br />

pH PROBE<br />

6<br />

SECTION<br />

TYP<br />

pH PROBE INSTALLATION<br />

OPEN GRATING/ACCESS COVER.<br />

REFER TO DETAIL LOCATION ON<br />

DWG 000-D-2003<br />

COIL AND SUPPORT pH PROBE CABLE<br />

UNDER OPEN GRATING/ACCESS COVER<br />

WITH SST HARDWARE. ALLOW ADEQUATE<br />

CABLE TO REMOVE PROBE FROM PIPE GUIDE<br />

6.35 THICK SST PLATE<br />

SIZED TO SUIT, TYPICAL<br />

40 SST STD WALL<br />

PIPE, TYPICAL<br />

4 - 16 HILTI RE500<br />

SST EPOXY ANCHORS,<br />

TYPICAL<br />

EXISTING CONCRETE<br />

TANK WALL<br />

6 POLYETHYLENE TUBING<br />

FOR SHX (SPARE)<br />

STRING FOR FUTURE<br />

CABLE/TUBING PULLS<br />

SODIUM HYDROXIDE (SHX) CONTAINMENT PIPE<br />

2 DETAIL<br />

NTS<br />

000-D-2001, 000-D-2006<br />

INSULATION. REFER TO<br />

SPECIFICATION 15080<br />

40 SCH 40 PVC<br />

CONTAINMENT PIPE<br />

6 POLYETHYLENE TUBING<br />

FOR SHX<br />

HEAT TRACING CABLE<br />

0<br />

JPN RC<br />

424251<br />

000-D-5002<br />

FILENAME: 000-D-5002_424251.dgn PLOT DATE: 2012\07\25 PLOT TIME: 5:50:14 PM<br />

DISTRICT M UNICIPALITY<br />

DATE<br />

PROJ<br />

DWG<br />

OF M USKOKA<br />

SHEET<br />

FAIRYVIEW W ATER TREATMENT PLANT<br />

PROCESS MECHANICAL<br />

MB<br />

JPN<br />

ISSUED FOR TENDER<br />

07/2012<br />

PHASE I UPGRADES<br />

DETAILS (2)<br />

VERIFY SCALE<br />

BAR IS 25mm ON<br />

APVD<br />

BY<br />

REVISION<br />

DATE<br />

NO.<br />

CONTRACT 12-432-253<br />

ORIGINAL DRAWING.<br />

0 25 MM<br />

APVD<br />

CHK<br />

DSGN DR<br />

ET JPN<br />

2012/07/27<br />

16of62<br />

CH2M HILL 2012. ALL RIGHTS RESERVED.<br />

c<br />

THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF<br />

CH2M HILL AND IS NOT TO BE USED, IN W HOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE W RITTEN AUTHORIZATION OF CH2MHILL.<br />

REUSE OF DOCUMENTS:<br />

ISSUED FOR TENDER