CONFIGURATION<br />
The initial bed height screen has a YES or NO option for the sensor configuration. Press N for NO and Y for<br />
YES. The default for the bed height sensor is NO.<br />
If NO, the following screen will appear:<br />
If YES, the following screen will appear:<br />
CALIBRATION<br />
BED DOWN This value can be entered manually or automatically captured. This is the voltage from the<br />
sensor when the bed is completely down.<br />
11001-1258-200311<br />
Manual Entry Select the BED DOWN text and enter the voltage from the sensor when<br />
the dump bed is completely down.<br />
Automatic Entry Insure that the Dump bed is completely down and the sensor is installed<br />
and connected. Select the BED DOWN text and press “C” to capture<br />
the sensor voltage.<br />
BED ALARM This value can be entered manually or automatically captured. This is the voltage when the<br />
bed has exceeded it normal operating height.<br />
<strong>Control</strong> Point version 6.40 software addendum 17