TANK CAPCAITY This is the maximum holding capacity of the tank.<br />

NOTE: The alarm is only active when the Master Switch is in the AUTO position. The alarm will activate<br />

audible and visual signals when the tank level drops below the TANK ALARM. When the Master Switch is<br />

turned OFF and then returns to AUTO, the alarm will NOT be reissued until the level goes above the TANK<br />

ALARM plus the 5% hysteresis or until the unit has been turned off.<br />

Gate Height Sensor<br />

This sensor will compensate for changes in the gate height from the original calibrated gate setting, allowing<br />

the application of granular material to be more accurate by adjusting the conveyor speed to maintain the<br />

selected application rate based on the current gate height. (IE. If the gate height is increased, the conveyor<br />

will slow down and if the gate height is decreased the conveyor will speed up.) The gate height sensor is to<br />

be connected to the main harness lead labeled GATE on the current <strong>Control</strong> Point harnesses and PRES-<br />

SURE on the earlier version harnesses. Versions 6.10 and newer software have removed pressure control<br />

from the <strong>Control</strong> Point. The new software now utilizes the pressure sensor input for the gate height. If you<br />

have a pressure controlled liquid system you can not use the version 6.10 or newer software. When enabled,<br />

the gate height will be displayed to the nearest .1 of an inch or 1 centimeter in the lower right corner of<br />

the operate screen. The configuration and calibration of the gate height sensor is found under Miscellaneous<br />

(F12), More (6), Gate Height Sensor (1).<br />

11001-1258-200311<br />

<strong>Control</strong> Point version 6.40 software addendum 5