<strong>Telecommunication</strong>-Outdoor <strong>Cables</strong><br />
Polyethylene-insulated subscriber cable TK-..x4/..-PE-ALT<br />
conductor diameter 0.6 mm conductor diameter 0.8 mm<br />
Type number of outer diameter weight outer diameter weight<br />
double cores approx. mm approx. kg/km approx. mm approx. kg/km<br />
TK 1x4/..-PE-ALT 2 7.8 65 8.8 83<br />
TK 3x4/..-PE-ALT 6 10.6 112 12.6 164<br />
TK 5x4/..-PE-ALT 10 12.1 159 15.3 250<br />
TK10x4/..-PE-ALT 20 16.6 270 20.1 406<br />
TK15x4/..-PE-ALT 30 18.4 356 22.7 541<br />
TK20x4/..-PE-ALT 40 21.4 453 26.8 731<br />
TK30x4/..-PE-ALT 60 22.9 590 29.0 975<br />
TK40x4/..-PE-ALT 80 25.7 773 32.1 1242<br />
TK50x4/..-PE-ALT 100 28.6 926 36.4 1543<br />
TK60x4/..-PE-ALT 120 30.2 1076 38.5 1802<br />
TK100x4/..-PE-ALT 200 38.5 1726 49.6 2912<br />
Application<br />
In all kinds of operating premises (excepted locations with special protection<br />
demands - like in fire or highly combustible premises). In telecommunication<br />
network systems and similar systems, for example as PTT subscriber’s cable.<br />
Construction<br />
Conductor: solid, bare copper wire Ø 0.6 / 0.8 mm<br />
Insulation: PE (PE)<br />
Colour code: tracer quad: WT-OR-TQ-VI<br />
counter quad: WT-GN-TQ-VI<br />
standard quad 1: WT-BN-TQ-VI<br />
standard quad 2: WT-GY-TQ-VI<br />
Cable make up: 4 cores twisted to quads, quads stranded together in<br />
concentric layers to cable core, cable core wrapping<br />
with plastic foil<br />
Sheath: PE single-coated aluminium foil bonded with the PEouter<br />
sheath (ALT), black, one or two drain wire(s)<br />
Design<br />
2-200 DC (1 up to 100 quads)<br />
Laying<br />
suitable for underground laying and pulling into conduits, ducts<br />
Marking<br />
< ..x4/.. PE-ALT> <br />
<br />
C40<br />
Ø<br />
0.6<br />
mutual capacitance<br />
Ø<br />
0.8<br />
dimension of<br />
conductor<br />
cable elements<br />
Technical Details (at 20°C)<br />
standard acc. PTT 844.14<br />
conductor diameter 0.6 0.8 mm<br />
loop resistance ≤ 133 ≤ 73.5 Ω/km<br />
insulation resistance ≥ 10 ≥ 10 GΩkm<br />
mutual capacitance spec.value 40±9 40±9 nF/km<br />
(at f=800Hz) mean value 1) 40±3 40±3 nF/km<br />
capacitance unbalance k 1<br />
(at f=800Hz) mean value 1) ≤ 50 ≤ 50 pF/230m<br />
capacitance unbalance k 9-12<br />
(at f=800Hz) mean value 1) ≤ 30 ≤ 30 pF/230m<br />
capacitance unbalance e a1<br />
(at f=800Hz) ≤ 400 ≤ 400 pF/230m<br />
mean value 1) ≤ 100 ≤ 100 pF/230m<br />
dielectric strength<br />
conductor/conductor 500V/50Hz<br />
conductor/shield 2000V/50Hz<br />
1) for cables with 20 and more elements<br />
<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 25<br />
DC<br />
n<br />
number of<br />
double cores<br />
filling<br />
overall shield,<br />
armouring