10.06.2013 Views

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Telecommunication</strong>-Indoor <strong>Cables</strong><br />

Halogenfree, shielded installation cable CU/PE/FOL/AL/FRNC (55 nF)<br />

Type number of outer diameter weight<br />

double cores approx. mm approx. kg/km<br />

CU/PE/FOL/AL/FRNC 2x2x0.5 2 5.0 27<br />

CU/PE/FOL/AL/FRNC 4x2x0.5 4 6.0 39<br />

CU/PE/FOL/AL/FRNC 8x2x0.5 8 7.0 62<br />

CU/PE/FOL/AL/FRNC 10x2x0.5 10 8.0 77<br />

CU/PE/FOL/AL/FRNC 20x2x0.5 20 11.0 137<br />

CU/PE/FOL/AL/FRNC 30x2x0.5 30 13.0 202<br />

CU/PE/FOL/AL/FRNC 50x2x0.5 50 16.0 310<br />

CU/PE/FOL/AL/FRNC 100x2x0.5 100 22.0 577<br />

CU/PE/FOL/AL/FRNC 200x2x0.5 200 29.0 1106<br />

Application<br />

For telecommunication and signal transmission with high safety standards and<br />

to protect people and real values against fire as well as telecommunication<br />

cable for measuring and controlling purposes in industrial plants. In case of fire<br />

no corrosive gases will be emitted.<br />

Construction<br />

Conductor: solid, bare copper wire Ø 0.5 mm (CU)<br />

Insulation: PE (PE)<br />

Colour code: WT/BU; WT/OR; WT/GN; WT/BN; WT/GY; RD/BU;<br />

RD/OR; RD/GN; RD/BN; RD/GY<br />

Cable make up: 2 cores twisted to pairs, 10 pairs stranded together to<br />

units, units stranded together in concentric layers to<br />

cable core, units identified by numbers, cable core<br />

wrapping of plastic foil (FOL)<br />

Drain wire: tinned copper wire Ø 0.5 mm<br />

Screening: aluminium laminated plastic foil (AL), rip cord<br />

Sheath: FRNC-compound (FRNC), grey (RAL 7032)<br />

Laying<br />

for indoor and outdoor laying, not suitable for earth laying<br />

Marking<br />

<br />

C55<br />

Ø<br />

0.5<br />

mutual capacitance<br />

dimension of<br />

conductor<br />

cable elements<br />

Technical Details (at 20°C)<br />

standard TDK-TS 900 012, IEC 60332-1<br />

<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 39<br />

DC<br />

n<br />

conductor diameter 0.5 mm<br />

conductor resistance (core) ≤ 97.8 Ω/km<br />

differential resistance ≤ 2 %<br />

insulation resistance ≥ 500 MΩkm<br />

mutual capacitance<br />

(at f=800Hz) pair ≤ 64 nF/km<br />

mean value ≤ 55 nF/km<br />

capacitance unbalance k<br />

(at f=800Hz) pair-pair ≤ 250 pF/500m<br />

mean value 95% ≤ 150 nF/500m<br />

operating voltage ≤ 50 V AC<br />

≤ 75 V DC<br />

dielectric strength<br />

conductor/conductor 1500 V/DC 1min<br />

temperature range<br />

during installation -5 up to +50 °C<br />

for stationary conditions up to +70 °C<br />

number of<br />

double cores<br />

filling<br />

overall shield,<br />

armouring