<strong>Telecommunication</strong>-Indoor <strong>Cables</strong><br />
Halogenfree, shielded installation cable CU/PE/FOL/AL/FRNC (55 nF)<br />
Type number of outer diameter weight<br />
double cores approx. mm approx. kg/km<br />
CU/PE/FOL/AL/FRNC 2x2x0.5 2 5.0 27<br />
CU/PE/FOL/AL/FRNC 4x2x0.5 4 6.0 39<br />
CU/PE/FOL/AL/FRNC 8x2x0.5 8 7.0 62<br />
CU/PE/FOL/AL/FRNC 10x2x0.5 10 8.0 77<br />
CU/PE/FOL/AL/FRNC 20x2x0.5 20 11.0 137<br />
CU/PE/FOL/AL/FRNC 30x2x0.5 30 13.0 202<br />
CU/PE/FOL/AL/FRNC 50x2x0.5 50 16.0 310<br />
CU/PE/FOL/AL/FRNC 100x2x0.5 100 22.0 577<br />
CU/PE/FOL/AL/FRNC 200x2x0.5 200 29.0 1106<br />
Application<br />
For telecommunication and signal transmission with high safety standards and<br />
to protect people and real values against fire as well as telecommunication<br />
cable for measuring and controlling purposes in industrial plants. In case of fire<br />
no corrosive gases will be emitted.<br />
Construction<br />
Conductor: solid, bare copper wire Ø 0.5 mm (CU)<br />
Insulation: PE (PE)<br />
Colour code: WT/BU; WT/OR; WT/GN; WT/BN; WT/GY; RD/BU;<br />
RD/OR; RD/GN; RD/BN; RD/GY<br />
Cable make up: 2 cores twisted to pairs, 10 pairs stranded together to<br />
units, units stranded together in concentric layers to<br />
cable core, units identified by numbers, cable core<br />
wrapping of plastic foil (FOL)<br />
Drain wire: tinned copper wire Ø 0.5 mm<br />
Screening: aluminium laminated plastic foil (AL), rip cord<br />
Sheath: FRNC-compound (FRNC), grey (RAL 7032)<br />
Laying<br />
for indoor and outdoor laying, not suitable for earth laying<br />
Marking<br />
<br />
C55<br />
Ø<br />
0.5<br />
mutual capacitance<br />
dimension of<br />
conductor<br />
cable elements<br />
Technical Details (at 20°C)<br />
standard TDK-TS 900 012, IEC 60332-1<br />
<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 39<br />
DC<br />
n<br />
conductor diameter 0.5 mm<br />
conductor resistance (core) ≤ 97.8 Ω/km<br />
differential resistance ≤ 2 %<br />
insulation resistance ≥ 500 MΩkm<br />
mutual capacitance<br />
(at f=800Hz) pair ≤ 64 nF/km<br />
mean value ≤ 55 nF/km<br />
capacitance unbalance k<br />
(at f=800Hz) pair-pair ≤ 250 pF/500m<br />
mean value 95% ≤ 150 nF/500m<br />
operating voltage ≤ 50 V AC<br />
≤ 75 V DC<br />
dielectric strength<br />
conductor/conductor 1500 V/DC 1min<br />
temperature range<br />
during installation -5 up to +50 °C<br />
for stationary conditions up to +70 °C<br />
number of<br />
double cores<br />
filling<br />
overall shield,<br />
armouring