<strong>Telecommunication</strong>-Indoor <strong>Cables</strong><br />

Halogenfree, unshielded switchboard cable NOPTK<br />

Type number of outer diameter weight<br />

cores approx. mm approx. kg/km<br />

NOPTK 2x0.6 2 3.0 13<br />

NOPTK 3x0.6 3 3.0 16<br />

NOPTK 4x0.6 4 3.0 19<br />

NOPTK 5x0.6 5 4.0 23<br />

NOPTK 6x0.6 6 4.0 27<br />

NOPTK 8x0.6 8 5.0 34<br />

NOPTK 10x0.6 10 5.0 41<br />

NOPTK 12x0.6 12 5.0 44<br />

Application<br />

As switchboard cable in telecommunicatuion and information systems, with<br />

high safety standards and to protect people and real values against fire; as<br />

connecting cable between racks and main distribution frames in telecommunication<br />

exchanges and railway interlocking cabins.<br />

Construction<br />

Conductor: solid tinned copper wire Ø 0.6 mm<br />

Insulation: PE<br />

Colour code: RD, BU, YE, WT, GN, BK, GY, BN, VI, OR, PK, LGY<br />

Cable make up: cores twisted together in concentric layers, cable core<br />

wrapping with tapes (> 5 pairs)<br />

Sheath: FRNC-compound, white<br />

Laying<br />

for indoor and outdoor applications, not suitable for direct earth laying<br />

Marking<br />

-<br />

C70<br />

Ø<br />

0.6<br />

mutual capacitance<br />

dimension of<br />

conductor<br />

cable elements<br />

Technical Details (at 20°C)<br />

standard NKT; IEC 60332-1<br />

conductor diameter 0.6 mm<br />

conductor resistance (core) ≤ 67.9 Ω/km<br />

insulation resistance ≥ 1.5 GΩkm<br />

mutual capacitance<br />

(at f=800Hz) ≤ 70 nF/km<br />

operating voltage ≤ 50 V AC<br />

≤ 75 V DC<br />

dielectric strength conductor/conductor 1500 V/DC 1min<br />

1000 V/AC<br />

bending radius > 10x outer diameter<br />

tensile strength ≤ 50 N/mm 2 overall<br />

copper cross section<br />

temperature range<br />

during installation -5 up to +50 °C<br />

for stationary conditions up to +70 °C<br />

number of<br />

double cores<br />

<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 43<br />

n<br />

filling<br />

overall shield,<br />

armouring