<strong>Telecommunication</strong>-Outdoor <strong>Cables</strong><br />
Polyethylene-insulated subscriber cable TK-..x4/..-PE-ALT-CLT<br />
conductor diameter 0.6 mm conductor diameter 0.8 mm<br />
Type number of outer diameter weight outer diameter weight<br />
double cores approx. mm approx. kg/km approx. mm approx. kg/km<br />
TK1x4/..-PE-ALT-CLT 2 12.0 161 13.0 190<br />
TK3x4/..-PE-ALT-CLT 6 14.8 238 16.8 310<br />
TK5x4/..-PE-ALT-CLT 10 16.3 300 19.5 425<br />
TK10x4/..-PE-ALT-CLT 20 20.8 459 24.3 631<br />
TK15x4/..-PE-ALT-CLT 30 22.6 564 26.9 794<br />
TK20x4/..-PE-ALT-CLT 40 25.6 692 31.0 1027<br />
TK30x4/..-PE-ALT-CLT 60 27.1 846 33.2 1295<br />
TK40x4/..-PE-ALT-CLT 80 29.9 1058 36.3 1594<br />
TK50x4/..-PE-ALT-CLT 100 32.8 1241 40.6 1940<br />
TK60x4/..-PE-ALT-CLT 120 34.4 1408 42.7 2221<br />
TK100x4/..-PE-ALT-CLT 200 42.7 2145 54.4 3496<br />
Application<br />
In all kinds of operating premises (excepted locations with special protection<br />
demands - like in fire or highly combustible premises). In telecommunication<br />
network systems and similar systems, for example as PTT subscriber’s cable.<br />
Construction<br />
Conductor: solid, bare copper wire Ø 0.6 / 0.8 mm<br />
Insulation: PE (PE)<br />
Colour code: tracer quad: WT-OR-TQ-VI<br />
counter quad: WT-GN-TQ-VI<br />
standard quad 1: WT-BN-TQ-VI<br />
standard quad 2: WT-GY-TQ-VI<br />
Cable make up: 4 cores twisted to quads, quads stranded together in<br />
concentric layers to cable core, cable core wrapping<br />
with plastic foil<br />
Sheath: PE single-coated aluminium foil bonded with the PEouter<br />
sheath (ALT), black, one or two drain wire(s)<br />
Armouring: 2 layers of galvanized steel tape (CL)<br />
Protective cover: PE, black (T)<br />
Design<br />
2-200 DC (1 up to 100 quads)<br />
Laying<br />
suitable for underground laying and pulling into conduits, ducts<br />
Marking<br />
< ..x4/.. PE-ALT-CLT> <br />
<br />
C40<br />
Ø<br />
0.6<br />
mutual capacitance<br />
Technical Details (at 20°C)<br />
standard acc. PTT 844.14<br />
conductor diameter 0.6 0.8 mm<br />
loop resistance ≤ 133 ≤ 73.5 Ω/km<br />
insulation resistance ≥ 10 ≥ 10 GΩkm<br />
mutual capacitance spec. value 40±9 40±9 nF/km<br />
(at f=800Hz) mean value 1) 40±3 40±3 nF/km<br />
capacitance unbalance k 1<br />
(at f=800Hz) mean value 1) ≤ 50 ≤ 50 pF/230m<br />
capacitance unbalance k 9-12<br />
(at f=800Hz) mean value 1) ≤ 30 ≤ 30 pF/230m<br />
capacitance unbalance e a1<br />
(at f=800Hz) ≤ 400 ≤ 400 pF/230m<br />
mean value 1) ≤ 100 ≤ 100 pF/230m<br />
dielectric strength<br />
conductor/conductor 500V/50Hz<br />
conductor/shield 2000V/50Hz<br />
1) for cables with 20 and more elements<br />
26 <strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations<br />
Ø<br />
0.8<br />
dimension of<br />
conductor<br />
cable elements<br />
DC<br />
n<br />
number of<br />
double cores<br />
filling<br />
overall shield,<br />
armouring