10.06.2013 Views

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Telecommunication</strong>-Indoor <strong>Cables</strong><br />

Halogenfree, unshielded switchboard cable NOPT<br />

Type number of<br />

unit outer diameter weight<br />

double cores construction approx. mm approx. kg/km<br />

NOPT 1x2x0.6 1 1x2 3.0 11<br />

NOPT 1x4x0.6 2 1x4 4.0 22<br />

NOPT 2x2x0.6 2 2x2 5.0 24<br />

NOPT 3x2x0.6 3 3x2 5.0 32<br />

NOPT 4x2x0.6 4 4x2 5.0 38<br />

NOPT 5x2x0.6 5 5x2 6.0 46<br />

NOPT 6x2x0.6 6 6x2 7.0 54<br />

NOPT 7x2x0.6 7 7x2 7.0 61<br />

NOPT 8x2x0.6 8 8x2 7.0 67<br />

NOPT 10x2x0.6 10 10x2 8.0 80<br />

NOPT 12x2x0.6 12 12x2 9.0 95<br />

NOPT 15x2x0.6 15 15x2 11.0 118<br />

NOPT 20x2x0.6 20 20x2 12.0 153<br />

NOPT 25x2x0.6 25 25x2 13.0 190<br />

NOPT 30x2x0.6 30 3x10 14.0 226<br />

NOPT 40x2x0.6 40 4x10 16.0 299<br />

NOPT 50x2x0.6 50 5x10 17.0 372<br />

Application<br />

As switchboard cable in telecommunicatuion and information systems, with<br />

high safety standards and to protect people and real values against fire; as<br />

connecting cable between racks and main distribution frames in telecommunication<br />

exchanges and railway interlocking cabins.<br />

Construction<br />

Conductor: solid, tinned copper wire Ø 0.6 mm<br />

Insulation: PE<br />

Colour code: according to IEC 60189-2 colour code CN-1<br />

Cable make up: 2 cores twisted to pairs, 25 (10) pairs stranded together<br />

to units, units cabled together in concentric layers to<br />

cable core, units (or groups of units) are identified by<br />

numbers, cable core wrapping of plastic foil (> 5 pairs)<br />

Sheath: FRNC-compound, white<br />

Laying<br />

for indoor and outdoor applications, not suitable for direct earth laying<br />

Marking<br />

-<br />

C70<br />

Ø<br />

0.6<br />

mutual capacitance<br />

dimension of<br />

conductor<br />

cable elements<br />

Technical Details (at 20°C)<br />

standard NKT; IEC 60189-2, IEC 60332-1<br />

<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 41<br />

DC<br />

n<br />

conductor diameter 0.6 mm<br />

conductor resistance ≤ 67.9 Ω/km<br />

insulation resistance ≥ 500 MΩkm<br />

mutual capacitance<br />

(at f=800Hz) mean value ≤ 70 nF/km<br />

capacitance unbalance k<br />

(at f=800Hz) ≤ 400 pF/500m<br />

operating voltage ≤ 50 V AC<br />

≤ 75 V DC<br />

dielectric strength<br />

conductor/conductor 1500 V/DC 1min<br />

1000 V/AC<br />

bending radius > 10x outer diameter<br />

tensile strength ≤ 50 N/mm 2 overall<br />

copper cross section<br />

temperature range<br />

during installation -5 up to +50 °C<br />

for stationary conditions up to +70 °C<br />

number of<br />

double cores<br />

filling<br />

overall shield,<br />

armouring

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!