Telecommunication Copper Cables - PENGG KABEL GmbH
Telecommunication Copper Cables - PENGG KABEL GmbH
Telecommunication Copper Cables - PENGG KABEL GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Telecommunication</strong>-Indoor <strong>Cables</strong><br />
Halogenfree, unshielded switchboard cable NOPT<br />
Type number of<br />
unit outer diameter weight<br />
double cores construction approx. mm approx. kg/km<br />
NOPT 1x2x0.6 1 1x2 3.0 11<br />
NOPT 1x4x0.6 2 1x4 4.0 22<br />
NOPT 2x2x0.6 2 2x2 5.0 24<br />
NOPT 3x2x0.6 3 3x2 5.0 32<br />
NOPT 4x2x0.6 4 4x2 5.0 38<br />
NOPT 5x2x0.6 5 5x2 6.0 46<br />
NOPT 6x2x0.6 6 6x2 7.0 54<br />
NOPT 7x2x0.6 7 7x2 7.0 61<br />
NOPT 8x2x0.6 8 8x2 7.0 67<br />
NOPT 10x2x0.6 10 10x2 8.0 80<br />
NOPT 12x2x0.6 12 12x2 9.0 95<br />
NOPT 15x2x0.6 15 15x2 11.0 118<br />
NOPT 20x2x0.6 20 20x2 12.0 153<br />
NOPT 25x2x0.6 25 25x2 13.0 190<br />
NOPT 30x2x0.6 30 3x10 14.0 226<br />
NOPT 40x2x0.6 40 4x10 16.0 299<br />
NOPT 50x2x0.6 50 5x10 17.0 372<br />
Application<br />
As switchboard cable in telecommunicatuion and information systems, with<br />
high safety standards and to protect people and real values against fire; as<br />
connecting cable between racks and main distribution frames in telecommunication<br />
exchanges and railway interlocking cabins.<br />
Construction<br />
Conductor: solid, tinned copper wire Ø 0.6 mm<br />
Insulation: PE<br />
Colour code: according to IEC 60189-2 colour code CN-1<br />
Cable make up: 2 cores twisted to pairs, 25 (10) pairs stranded together<br />
to units, units cabled together in concentric layers to<br />
cable core, units (or groups of units) are identified by<br />
numbers, cable core wrapping of plastic foil (> 5 pairs)<br />
Sheath: FRNC-compound, white<br />
Laying<br />
for indoor and outdoor applications, not suitable for direct earth laying<br />
Marking<br />
-<br />
C70<br />
Ø<br />
0.6<br />
mutual capacitance<br />
dimension of<br />
conductor<br />
cable elements<br />
Technical Details (at 20°C)<br />
standard NKT; IEC 60189-2, IEC 60332-1<br />
<strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations 41<br />
DC<br />
n<br />
conductor diameter 0.6 mm<br />
conductor resistance ≤ 67.9 Ω/km<br />
insulation resistance ≥ 500 MΩkm<br />
mutual capacitance<br />
(at f=800Hz) mean value ≤ 70 nF/km<br />
capacitance unbalance k<br />
(at f=800Hz) ≤ 400 pF/500m<br />
operating voltage ≤ 50 V AC<br />
≤ 75 V DC<br />
dielectric strength<br />
conductor/conductor 1500 V/DC 1min<br />
1000 V/AC<br />
bending radius > 10x outer diameter<br />
tensile strength ≤ 50 N/mm 2 overall<br />
copper cross section<br />
temperature range<br />
during installation -5 up to +50 °C<br />
for stationary conditions up to +70 °C<br />
number of<br />
double cores<br />
filling<br />
overall shield,<br />
armouring