Behaviour in Case of Fire, Fire Away Line, Fire Load<br />

In the European standards EN 50167, EN 50168 and EN 50169 data<br />

cables with halogen-free outer sheath are required. The consideration<br />

and adherence to these standards are recommended particularly with<br />

public setting e.g. hospitals, schools and airports. In addition with<br />

other buildings with high person or real value concentration a use of<br />

halogen-free cables is practical.<br />

Cable with PVC-sheath<br />

In the case of fire standard PVC materials can transmit fires and form<br />

hydrochloric acid (HCI) by splitting off hydrogen chloride gas in<br />

connection with moisture (e.g. fire fighting water). It continues to co me<br />

to a strong smoke development with burning PVC (polyvinyl chloride)<br />

and the corrosive damage at buildings and equipment can often devastating<br />

extents assume, which exceed far the actual fire damage.<br />

<strong>Cables</strong> with halogenfree sheath<br />

Hereby materials are used, which do not contain halogens (e.g. chlorine)<br />

and which do not set free corrosive gases in the case of fire. Also the<br />

proportion of toxic gases is reduced to a minimum, and smoke development<br />

and fire away line are hardly still available or possible. Designation<br />

notes at the cable are e.g. the abbreviations FRNC or LSOH.<br />

In detail these designations are meaning:<br />

FR – flame retardant<br />

(fire-away-line-restraining)<br />

NC – non corrosiv<br />

(no corrosive constituents)<br />

LS – low smoke<br />

(low smoke development)<br />

0H – zero halogen (halogen-free)<br />

Another big advantage by using such materials is, that the free view<br />

on gears and escape routes is kept. Please note that you have to take<br />

care that such kinds of materials are also used by other products ,<br />

e.g. power cables or cable run channels.<br />

Fire load [kWh/m], [MJ/m]<br />

In each building there are many different inflammable installations or<br />

products. Also cable and cores (although hidden in intermediate ceilings<br />

or channels), which can in particular represent a substantial<br />

component in administration buildings belong to them. These cables<br />

have most divergent powers (heat values) and the total fire load of a<br />

building could clearly increase. Therefore you should be pay attention<br />

to the fact, when planning that the fire load quantities are kept as<br />

small as possible.<br />

Testing method according to IEC 60332-1<br />

Samples<br />

From the end of the tested cable a sample piece of 600±25 mm is taken.<br />

Preparation (fig.1)<br />

Propane from cylinder with burner, flame height 175 mm.<br />

Sample is hung up vertically into the center of a metal box, (metal<br />

box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open).<br />

Flame cone of the gas burner has to be fixed in an angle of 45° approx.<br />

100 mm above the lower sample.<br />

With cable diameter up to 50 mm one burner is used, with cable diameter<br />

over 50 mm two burners are used.<br />

Execution<br />

t = duration of the flaming action in s<br />

m = weight of the sample in g<br />

Analysis<br />

The test is considered as positively passed if the sample did not burn<br />

or the flames automatically go out and the fire damage does not<br />

reach the upper end of the sample.<br />

Fire-pure e.g. soot lining and colour modification are not does claimed.<br />

Samples<br />

From the end of the tested cable a sample piece of 600±25 mm is taken.<br />

Preparation<br />

Propane from cylinder with burner, flame height 125 mm.<br />

Sample is hung up vertically into the center of a metal box, (metal<br />

box: h=1200±25 mm, b=300±25 mm, t=450±25 mm, front open).<br />

Flame cone of the gas burner has to be fixed in an angle of 45° approx.<br />

100 mm above the lower sample.<br />

Execution<br />

max. 20s<br />

t = 60 + —— m<br />

25<br />

Testing method according to IEC 60332-2<br />

Analysis<br />

The test is considered as positively passed if the sample did not burn<br />

or the flames automatically go out and the fire damage does not<br />

reach the upper end of the sample.<br />

Fire-pure e.g. soot lining and colour modification are not does claimed.<br />