10.06.2013 Views

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

Telecommunication Copper Cables - PENGG KABEL GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Telecommunication</strong>-Outdoor <strong>Cables</strong><br />

Foam-skin-PE-insulated, filled local telecommunication cable QV ..x4x..<br />

conductor diameter 0.4 mm conductor diameter 0.6 mm conductor diameter 0.8 mm<br />

Type number of extra outer diameter weight outer diameter weight outer diameter weight<br />

double cores quads approx. mm approx. kg/km approx. mm approx. kg/km approx. mm approx. kg/km<br />

QV 1 x4x... 2 - 5.6 34 6.6 47 10.0 88<br />

QV 3 x4x... 6 - 7.6 58 9.4 97 12.0 156<br />

QV 5 x4x... 10 - 9.4 87 11.5 147 14.1 226<br />

QV 10 x4x... 20 - 11.5 139 15.0 262 18.3 401<br />

QV 15 x4x... 30 - 12.7 179 16.6 348 20.5 537<br />

QV 25 x4x... 50 - 15.6 278 20.1 532 25.5 859<br />

QV 35 x4x... 70 - 17.5 374 22.0 654 - -<br />

QV 50 x4x... 100 - 19.4 468 25.9 960 32.7 1590<br />

QV 75 x4x... 150 - 24.0 695 32.2 1436 41.2 2345<br />

QV 100 x4x... 200 - 27.1 905 36.5 1879 47.3 3118<br />

QV 150 x4x... 300 - 31.5 1290 43.1 2613 - -<br />

QV 200 x4x... 400 5 35.1 1665 48.5 3444 63.2 5969<br />

QV 300 x4x... 600 5 41.6 2398 58.3 5049 - -<br />

QV 400 x4x... 800 5 48.7 3241 69.3 7147 - -<br />

QV 500 x4x... 1000 5 53.5 3974 - - - -<br />

QV 600 x4x... 1200 5 59.4 4756 - - - -<br />

QV 800 x4x... 1600 10 66.4 6250 - - - -<br />

QV 1000 x4x... 2000 10 73.7 7752 - - - -<br />

Application<br />

Local distribution cables underground, primary cable between exchanges and<br />

distribution points and secondary cables to distribution points.<br />

Construction<br />

Conductor: plain annealed copper wire Ø 0.4 / 0.6 mm<br />

Insulation: foam-skin-PE<br />

Colour code: a-core: RD-GN-YE-BU-BN<br />

b-core: WT<br />

c-core: BK<br />

d-core: GY<br />

Stranding and coding: Basic strand (bs) of 5 quads (stranded) are laid up in<br />

concentric layers for cables up to max. 50 quads. For<br />

larger cables, basic strand (bs) are laid up in primary<br />

strand (ps) 25 quads, medium strand (ms) 50 quads or<br />

super strand (ss) 100 quads, and strands are laid up in<br />

concentric layers.<br />

The tracer unit is identified by an open red helix, the<br />

counter unit by a green one, all other units alternativly<br />

by an open yellow or blue helix.<br />

Filling: The interstices of the cable core are completely filled<br />

with petroleum jelly compound.<br />

Lapping:<br />

Screen /<br />

crepe paper<br />

Moisture Barrier: 0.15 mm aluminium tape coated with polyethylene<br />

0.05 mm on both sides, longitudinally applied with<br />

overlap<br />

Sheath: Polyethylene (PE), black<br />

Laying<br />

suitable for underground laying and drawing into conduits, ducts<br />

Marking<br />

<br />

<br />

28 <strong>Telecommunication</strong> <strong>Copper</strong> <strong>Cables</strong> • 09/2012 • © by <strong>PENGG</strong> <strong>KABEL</strong> <strong>GmbH</strong> • Subject to technical alterations<br />

C50<br />

Ø<br />

0.4<br />

mutual capacitance<br />

Ø<br />

0.6<br />

dimension of<br />

conductor<br />

cable elements<br />

Technical Details (at 20°C)<br />

standard MKM MATÁV MF 23836/1 and 4<br />

conductor diameter 0.4 0.6 mm<br />

loop resistance ≤ 300 ≤ 130 Ω/km<br />

mean value ≤ 288 ≤ 127,8 Ω/km<br />

insulation resistance ≥ 10 ≥ 10 GΩkm<br />

mutual capacitance<br />

(at f=800Hz) ≤ 50 ≤ 50 nF/km<br />

mean value ≤ 46 ≤ 46 nF/km<br />

capacitance unbalance k 1<br />

(at f=800Hz) 100% ≤ 800 ≤ 800 pF/300m<br />

98% ≤ 400 ≤ 400 pF/300m<br />

capacitance unbalance k 9-12<br />

(at f=800Hz) 100% ≤ 300 ≤ 300 pF/300m<br />

98% ≤ 100 ≤ 100 pF/300m<br />

capacitance unbalance e 1-2<br />

(at f=800Hz) 100% ≤ 800 ≤ 800 pF/300m<br />

DC<br />

n<br />

dielectric strength<br />

conductor/conductor 600 V/50Hz<br />

conductor/shield 2000 V/50Hz<br />

temperature range<br />

during installation -20 up to +50 °C<br />

for stationary conditions up to +70 °C<br />

F<br />

number of<br />

double cores<br />

filling<br />

overall shield,<br />

armouring