RX Manual 04/04 Rev. 6 OPERATING INSTRUCTIONS<br />

3.1 CONT<strong>RO</strong>LS AND INDICATORS<br />

3.0 OPERATING INSTRUCTIONS<br />

The controls and indicators used in the operation of the system are outlined in the MC10<br />

<strong>RO</strong> Controller manual located in the Appendix. The operator must be thoroughly familiar<br />

with the controls and their respective functions for proper operation and in order to<br />

maintain the quality of the product and eliminate unnecessary shutdowns.<br />

3.2 INITIAL STARTUP OF REVERSE OSMOSIS SYSTEM<br />

CAUTION<br />

CAUTION<br />

CAUTION<br />

Verify that all <strong>RO</strong> pressure vessel end cap retaining “U” pins are in place<br />

and secure.<br />

Do not run the motor for more than 30 seconds backwards or irreversible<br />

pump damage may result.<br />

The membrane feed pressure should not be allowed to exceed 250 psig at<br />

any time during operation.<br />

A. The operator should verify that appropriate pretreatment is in place and operating<br />

satisfactorily. Inappropriate or inoperative pretreatment can damage the<br />

membranes.<br />

B. Make all water, electrical, and drain connections according to installation<br />

instructions.<br />

C. Divert the outlet of the product water to a convenient drain.<br />

D. Turn on the feed water and the electrical power. With product water diverted to<br />

drain, fully open the reject throttling valve and close the reject recirculation<br />

throttling valve.<br />

E. Place the controller in the DIRECT FEED mode (refer to the Reverse Osmosis<br />

Controller manual in the Appendix for detailed instructions). Press the SYSTEM<br />

START button on the controller keypad to start the system, after a fifteen-second<br />

delay the pump should start.<br />

F. Check for proper pump rotation. (Please refer to the Pump Information, included<br />

in the Appendix of this manual for information concerning motor rotation and any<br />

other electrical requirements.)<br />

G. Set the reject recirculation flow to zero, but do not exceed 250 psig pressure to<br />

the membranes. Open the reject valve further if necessary to avoid over<br />

pressuring the system.<br />

CAUTION<br />

Do not use reject recirculation option for the first 4 hours of operation to<br />

speed flush up of the system.<br />

<strong>USF</strong>ilter 3-1