RX Manual 04/04 Rev. 6 T<strong>RO</strong>UBLESHOOTING<br />

5.4 HIGH PERCENT RECOVERY<br />

A. Verify that the reject, reject recycle and product flows are normal. If not, adjust to<br />

design flow rates using the Equipment Specifications located in the Appendix.<br />

B. Set the membrane pressure to 200 psig.<br />

C. If the product flow is high after adjusting the pressures and flows, the <strong>RO</strong><br />

membrane o-rings may be leaking. Check percent rejection.<br />

5.5 LOW SALT REJECTION<br />

A. Verify that the feed water temperature has not increased substantially from<br />

normal. High temperatures can affect percent rejection, as temperature<br />

increases, percent rejection decreases.<br />

B. Check product, reject, reject recycle flow rates and feed pressures per the<br />

Equipment Specifications in the Appendix, and adjust flows/pressures as<br />

necessary.<br />

C. Another possibility is high CO2 content in the inlet water. CO2 readily permeates<br />

the membrane. High CO2 content water will also have a pH of less than 6.0.<br />

D. <strong>RO</strong> membrane o-rings may not be seated correctly, check the percent rejection<br />

for each individual membrane housing. Remove membranes and verify o-rings<br />

are seated correctly on any that are below 90% rejection.<br />

E. If the above possibilities are eliminated, <strong>RO</strong> membranes are beginning to fail.<br />

They should be cleaned or replaced.<br />

NOTE: Contact your local <strong>USF</strong>ilter representative for assistance when the <strong>RO</strong> system<br />

requires cleaning.<br />

5.6 SYSTEM KEEPS SHUTTING OFF<br />

A. Observe the controller indicators to see if they indicate the cause for system<br />

shutdown, if the controller is shutting the unit down refer to the <strong>RO</strong> controller<br />

section of this manual for further discussion.<br />

B. The motor is equipped with automatic thermal overload protection. If the motor<br />

gets too hot it will shut down. After it has cooled it will restart. Excessive amp<br />

draw can cause the motor to get too hot.<br />

C. If an optional sensor is being used (Tank Level switch(es), Pretreatment<br />

Interlock), check to verify the sensor is not shutting off the system.<br />

5.7 SYSTEM SHUTOFF, LOW PRESSURE<br />

A. Verify that the feed water pressure is above 15 psig.<br />

B. Check the differential pressure across prefilter(s). It should be less than 10 psig,<br />

if not replace the prefilter cartridge filter and recheck feed pressure.<br />

<strong>USF</strong>ilter 5-2