RX Manual 04/04 Rev. 6 SYSTEM MAINTENANCE<br />
pump discharge, reject, and product cleaning ports on the <strong>RO</strong><br />
system to make these connections.<br />
d. The cleaning skid pump is turned on and run for 30 to 60 minutes.<br />
Adjust the reject flow. Verify the reject, reject recycle, and product<br />
flows and ensure sanitant reaches these areas of the system.<br />
CAUTION Monitor the solution temperature during recirculation. Do not<br />
allow the temperature to exceed 25° C (77° F).<br />
e. The cleaning pump can be shut down and the sanitant can soak<br />
for a maximum contact time of 2 hours, including recirculation<br />
time.<br />
f. Divert the product and reject lines to drain. Flush the sanitant<br />
from the system, filling the CIP with pretreated <strong>RO</strong> feedwater.<br />
Continue flushing for 15-30 minutes to remove the residual<br />
sanitant. When flushing the chemical from the system, close the<br />
reject recirculation valve. This will rinse chemical out more<br />
efficiently since it is not recycled back to the front end of the<br />
system.<br />
g. The <strong>RO</strong> is switched back to the normal feed source and run in the<br />
normal operating mode with the product diverted to drain until all<br />
residual sanitization chemicals are flushed from the system.<br />
h. The CIP tank and booster pump are drained and flushed with<br />
clean water.<br />
i. A new prefilter is installed in the system prefilter housing.<br />
NOTE: The introduction of sanitant by filling the prefilter housing has not been tested<br />
and proven to be an effective method of sanitizing the <strong>RO</strong> system.<br />
<strong>USF</strong>ilter 4-4