RX Manual 04/04 Rev. 6 T<strong>RO</strong>UBLESHOOTING<br />
5.1 SYSTEM INOPERATIVE<br />
5.0 T<strong>RO</strong>UBLESHOOTING<br />
A. Check to see if power to the unit is turned on.<br />
B. Verify the controller indicates that the system is on, if not press the system start<br />
button.<br />
C. Verify that the motor starter relay is engaging, if not reset the overload relay. If<br />
the overload relay fails to reset, replace the overload relay or contact your<br />
<strong>USF</strong>ilter representative for further assistance.<br />
D. Check the motor starter coil for proper operation and replace if necessary.<br />
E. With a voltmeter check that power is being supplied to the motor. If proper<br />
voltage is going to the motor but it does not run, replace the motor or contact<br />
your <strong>USF</strong>ilter representative for further assistance.<br />
5.2 LOW SYSTEM PRESSURE<br />
A. If the feed pressure before the prefilter is too low, check for obstruction in<br />
equipment and piping between feed source and <strong>RO</strong> unit.<br />
B. If the feed pressure after the prefilter is below normal, check for high differential<br />
pressure across the prefilter (plugging), replace the filter cartridge.<br />
C. If the membrane feed pressure is below normal, verify that the pump is running.<br />
D. Verify that the reject, reject recycle and product flows are normal. If not, adjust to<br />
design flow rates using the Equipment Specifications located in the Appendix and<br />
recheck membrane feed pressure.<br />
E. If the flows cannot be adjusted to the above flow rates, slowly close the reject<br />
and reject recirculation valves to observe the maximum pressure to the<br />
membrane. Do this only briefly and do not completely close the valve. If this<br />
pressure does not exceed 150 psig, repair or replace the pump/motor.<br />
5.3 LOW PERCENT RECOVERY<br />
A. Check product, reject, reject recycle flow rates and feed pressures to be sure<br />
they are normal; adjust flows as necessary.<br />
B. If feed to membrane pressure exceeds normal by 10% and product flow is lower<br />
than normal at a given temperature, the <strong>RO</strong> membranes are beginning to fail.<br />
They should be cleaned or replaced.<br />
NOTE: Contact your local <strong>USF</strong>ilter representative for assistance when the <strong>RO</strong> system<br />
requires cleaning.<br />
<strong>USF</strong>ilter 5-1