RX Manual 04/04 Rev. 6 T<strong>RO</strong>UBLESHOOTING<br />

5.1 SYSTEM INOPERATIVE<br />

5.0 T<strong>RO</strong>UBLESHOOTING<br />

A. Check to see if power to the unit is turned on.<br />

B. Verify the controller indicates that the system is on, if not press the system start<br />

button.<br />

C. Verify that the motor starter relay is engaging, if not reset the overload relay. If<br />

the overload relay fails to reset, replace the overload relay or contact your<br />

<strong>USF</strong>ilter representative for further assistance.<br />

D. Check the motor starter coil for proper operation and replace if necessary.<br />

E. With a voltmeter check that power is being supplied to the motor. If proper<br />

voltage is going to the motor but it does not run, replace the motor or contact<br />

your <strong>USF</strong>ilter representative for further assistance.<br />

5.2 LOW SYSTEM PRESSURE<br />

A. If the feed pressure before the prefilter is too low, check for obstruction in<br />

equipment and piping between feed source and <strong>RO</strong> unit.<br />

B. If the feed pressure after the prefilter is below normal, check for high differential<br />

pressure across the prefilter (plugging), replace the filter cartridge.<br />

C. If the membrane feed pressure is below normal, verify that the pump is running.<br />

D. Verify that the reject, reject recycle and product flows are normal. If not, adjust to<br />

design flow rates using the Equipment Specifications located in the Appendix and<br />

recheck membrane feed pressure.<br />

E. If the flows cannot be adjusted to the above flow rates, slowly close the reject<br />

and reject recirculation valves to observe the maximum pressure to the<br />

membrane. Do this only briefly and do not completely close the valve. If this<br />

pressure does not exceed 150 psig, repair or replace the pump/motor.<br />

5.3 LOW PERCENT RECOVERY<br />

A. Check product, reject, reject recycle flow rates and feed pressures to be sure<br />

they are normal; adjust flows as necessary.<br />

B. If feed to membrane pressure exceeds normal by 10% and product flow is lower<br />

than normal at a given temperature, the <strong>RO</strong> membranes are beginning to fail.<br />

They should be cleaned or replaced.<br />

NOTE: Contact your local <strong>USF</strong>ilter representative for assistance when the <strong>RO</strong> system<br />

requires cleaning.<br />

<strong>USF</strong>ilter 5-1