<strong>MB9A110</strong> <strong>Series</strong><br />

2. Recommended Operating Conditions<br />

Parameter Symbol Conditions<br />

Value<br />

Min Max<br />

Unit<br />

(Vss = AVss = 0.0V)<br />

Remarks<br />

Power supply voltage Vcc - 2.7 5.5 V<br />

Analog power supply voltage AVcc - 2.7 5.5 V AVcc = Vcc<br />

Analog reference voltage AVRH - AVss AVcc V<br />

FPT-100P-M20<br />

FPT-100P-M23<br />

FPT-80P-M21<br />

Operating<br />

temperature<br />

64<br />

FPT-80P-M37<br />

FPT-64P-M24<br />

FPT-64P-M38<br />

FPT-64P-M23<br />

FPT-64P-M39<br />

BGA-112P-M04<br />

Ta - - 40 + 105 °C<br />

When<br />

mounted on<br />

four-layer<br />

PCB<br />

FPT-100P-M06 Ta When<br />

mounted on<br />

double-sided<br />

single-layer<br />

PCB<br />

- 40 + 105 °C<br />

- 40 + 105 °C Icc ≤ 35mA<br />

- 40 + 85 °C Icc > 35mA<br />

<br />

The recommended operating conditions are required in order to ensure the normal operation of the<br />

semiconductor device. All of the device's electrical characteristics are warranted when the device is<br />

operated within these ranges.<br />

Always use semiconductor devices within their recommended operating condition ranges. Operation<br />

outside these ranges may adversely affect reliability and could result in device failure. No warranty is made<br />

with respect to uses, operating conditions, or combinations not represented on the data sheet. Users<br />

considering application outside the listed conditions are advised to contact their representatives beforehand.<br />