Measurement Guideline 3<br />

Measurement Guideline 3<br />

Special <strong>Test</strong> Considerations<br />

46<br />

Information for performing any of the FM, AM, or SSB measurements:<br />

Coaxial Cable<br />

Use short runs of high quality coaxial cable and high quality adapters<br />

when connecting the device connected to the <strong>Test</strong> <strong>Set</strong> to ensure the<br />

most accurate power measurement. Double shielded coaxial cable is<br />

recommended when performing measurements on Cavities and<br />

Duplexers.<br />

Cable and Adapter Loss<br />

Remember that cable and adapter losses and mismatch must be<br />

considered when measuring <strong>RF</strong> power at VHF/UHF frequencies. If<br />

losses are known, they can be entered using the CONFIGURATION<br />

screen. Once entered, the measurement results are adjusted<br />

accordingly.<br />

Incidental Audio<br />

Incidental audio into a built-in or attached microphone may cause<br />

inaccurate readings. Whenever possible, disable the microphone input<br />

or minimize ambient audio during the measurement.<br />

Transmitter’s DTMF, CTCSS, and or CDCSS Functions<br />

Verify that the Transmitter’s DTMF, CTCSS, and/or CDCSS functions<br />

are OFF (if equipped), unless otherwise specified.<br />

Receiver <strong>Test</strong> Loads<br />

If using the <strong>Test</strong> Load, the measurement must be performed with only<br />

the load connected to the Receiver’s audio output circuitry (internal<br />

speaker disconnected). If the external speaker jack does not break the