6 Test <strong>of</strong> a PXE based scintillator for <strong>Borexino</strong><br />

flash ADC board with the analog sum <strong>of</strong> all PMT signals was tested during some runs <strong>of</strong> the<br />

CTF2 (see chapter 5).<br />

In order to determine the efficiency <strong>of</strong> the «¬ discrimination a clean sample <strong>of</strong> « <strong>and</strong> ¬ events<br />

in the same energy range are needed. The only events that can be unambiguously identified as<br />

« or ¬ decays are the delayed coincidences from the Bi(¬)- Po(«) decay. I selected these<br />

events from all the 4 ton runs with the same selection criteria as for the determination <strong>of</strong> the<br />

U contamination. Further I restricted the sample to Bi events having energies in the same<br />

range as the Po alpha events: 200 - 400 photoelectrons for the Po alpha events <strong>and</strong> 100 -<br />

500 photoelectrons for the Bi beta events.<br />

The efficiency <strong>of</strong> the «¬ discrimination was determined by fitting a gaussian to the distribution<br />

<strong>of</strong> rØÓØ for « <strong>and</strong> ¬ events (see fig. 6.11). The ¬ identification efficiency was then<br />

fixed at 98 % <strong>and</strong> the corresponding « identification efficiency was calculated to be 84.6 %.<br />

Applying a radial cut on the Bi <strong>and</strong> Po events <strong>of</strong> Ö cm, yields for an « identification<br />

efficiency <strong>of</strong> 92.4 %. This improvement is due to the fact, that for events in the outermost<br />

region <strong>of</strong> the Inner Vessel, where total internal reflection plays an important role, the fraction<br />

<strong>of</strong> light registered at late times, is higher than in the inner regions <strong>of</strong> the Inner Vessel.<br />

96<br />

Figure 6.11: «¬ discrimination capability <strong>of</strong> PXE. Plotted is the tail-to-total ratio r ØÓØ <strong>of</strong><br />

Bi beta events (solid line) <strong>and</strong> Po alpha events (dashed line). For a ¬ identification efficiency<br />

<strong>of</strong> 98.0 %, the fit yields an « identification efficiency <strong>of</strong> 84.6 %.