PCMCIA Virtual File System (VFS)<br />

Changing the Virtual File System<br />

When you move to another VFS, the files stored on the PCMCIA Flash Module will not change.<br />

Before you change to another VFS, perform the following actions:<br />

3. Reboot the XP. During the Boot Firmware initialization, press the Escape key to stop the<br />

System Firmware from booting. (Typically, the Boot Firmware waits two seconds for user<br />

interruption before starting to boot the System Firmware.)<br />

4. To display the current VFS version on the PCMCIA module, enter the following command:<br />

xp-boot> pcshowversion<br />

5. At the Boot Firmware’s CLI prompt, enter the following to change from VFS1 to VFS2:<br />

xp-boot> pcmakeversion2<br />

To convert VFS2 to VFS1, enter the following command:<br />

xp-boot> pcmakeversion1<br />