Using the inform<strong>at</strong>ion derived from Figure 5, an inverting voltage compar<strong>at</strong>or is designed<br />
as shown in Figure 16. After applying dc power, Ei is adjusted to a ±7.5 V, 50Hz triangle<br />
wave.<br />
Figure 16 – Inverting voltage compar<strong>at</strong>or<br />
Using the oscilloscope, channel 1 is set to measure the input voltage <strong>at</strong> pin 2. Channel 2<br />
measures the voltage across the load resistance RL. Figure 17 displays these voltages<br />
versus time. +Vs<strong>at</strong> measures +12.50V and –Vs<strong>at</strong> measures -11.44V.<br />
23