◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Administrator’s<br />
Guide<br />
◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Comm<strong>and</strong> Line<br />
Interface (CLI) Reference Guide<br />
◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Installation Guide<br />
Overview of the deployment concepts<br />
Common terms for<br />
the deployment<br />
The new generation of EMC <strong>Brocade</strong> storage virtualization solutions<br />
is delivered both as the <strong>AP</strong>-<strong>7600B</strong> st<strong>and</strong>-alone switch, <strong>and</strong> as the<br />
<strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18 blade, which slots into a <strong>Brocade</strong> EC-48000B director.<br />
Both offer 16 Fibre Channel ports.<br />
The management of these two platforms is divided between the<br />
following components:<br />
◆ Control processor (CP) — Runs the Fabric OS <strong>and</strong> h<strong>and</strong>les layer 2<br />
communications.<br />
◆ Blade processor (BP) — Runs the storage application services<br />
(SAS) <strong>and</strong> manages the virtualization layer. The Unisys<br />
<strong>SafeGuard</strong> <strong>Solutions</strong> SAS agent is installed on the BP.<br />
The CP <strong>and</strong> BP have unique IP addresses. You can use the<br />
ipaddrshow switch CLI comm<strong>and</strong> to display the IP address for each.<br />
It may be helpful to refer to Figure 2 on page 8 while reading the<br />
following paragraphs:<br />
◆ Data path controller — Both the <strong>AP</strong>-<strong>7600B</strong> <strong>and</strong> <strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18<br />
have two data path controllers (DPCs). The DPC h<strong>and</strong>les most<br />
I/O operations without further CPU involvement. You can<br />
associate a set of virtual initiators <strong>and</strong> virtual targets with each<br />
DPC.<br />
Note: When working with Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Release 6.1, in<br />
frame redirect mode, both DPCs are utilized. Otherwise, only one DPC is<br />
utilized.<br />
◆ Host initiator — Each HBA on a host machine can be a host<br />
initiator (HI). Each host initiator is represented by a single virtual<br />
initiator on each DPC that it uses.<br />
4 Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> <strong>Deploying</strong> <strong>Brocade</strong> <strong>AP</strong>-<strong>7600B</strong> <strong>and</strong> <strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18 Devices Technical Notes