18.08.2013 Views

SafeGuard Solutions Deploying Brocade AP-7600B and PB-48K ...

SafeGuard Solutions Deploying Brocade AP-7600B and PB-48K ...

SafeGuard Solutions Deploying Brocade AP-7600B and PB-48K ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Administrator’s<br />

Guide<br />

◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Comm<strong>and</strong> Line<br />

Interface (CLI) Reference Guide<br />

◆ Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Replication Appliance Installation Guide<br />

Overview of the deployment concepts<br />

Common terms for<br />

the deployment<br />

The new generation of EMC <strong>Brocade</strong> storage virtualization solutions<br />

is delivered both as the <strong>AP</strong>-<strong>7600B</strong> st<strong>and</strong>-alone switch, <strong>and</strong> as the<br />

<strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18 blade, which slots into a <strong>Brocade</strong> EC-48000B director.<br />

Both offer 16 Fibre Channel ports.<br />

The management of these two platforms is divided between the<br />

following components:<br />

◆ Control processor (CP) — Runs the Fabric OS <strong>and</strong> h<strong>and</strong>les layer 2<br />

communications.<br />

◆ Blade processor (BP) — Runs the storage application services<br />

(SAS) <strong>and</strong> manages the virtualization layer. The Unisys<br />

<strong>SafeGuard</strong> <strong>Solutions</strong> SAS agent is installed on the BP.<br />

The CP <strong>and</strong> BP have unique IP addresses. You can use the<br />

ipaddrshow switch CLI comm<strong>and</strong> to display the IP address for each.<br />

It may be helpful to refer to Figure 2 on page 8 while reading the<br />

following paragraphs:<br />

◆ Data path controller — Both the <strong>AP</strong>-<strong>7600B</strong> <strong>and</strong> <strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18<br />

have two data path controllers (DPCs). The DPC h<strong>and</strong>les most<br />

I/O operations without further CPU involvement. You can<br />

associate a set of virtual initiators <strong>and</strong> virtual targets with each<br />

DPC.<br />

Note: When working with Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> Release 6.1, in<br />

frame redirect mode, both DPCs are utilized. Otherwise, only one DPC is<br />

utilized.<br />

◆ Host initiator — Each HBA on a host machine can be a host<br />

initiator (HI). Each host initiator is represented by a single virtual<br />

initiator on each DPC that it uses.<br />

4 Unisys <strong>SafeGuard</strong> <strong>Solutions</strong> <strong>Deploying</strong> <strong>Brocade</strong> <strong>AP</strong>-<strong>7600B</strong> <strong>and</strong> <strong>PB</strong>-<strong>48K</strong>-<strong>AP</strong>4-18 Devices Technical Notes

Hooray! Your file is uploaded and ready to be published.