NOTE: A program must have the MV/PS control option enabled to permit individual stations<br />

assigned to the program to be excluded from MV/PS operation. In other words, assigning MV/PS<br />

operation by station is not applicable unless MV/PS operation for its assigned program is enabled.<br />

• Master Valve/Pump Start Operation by Program<br />

1. Set the Program Switch to select program A, B, C, or D.<br />

2. Turn the Function Dial to Special Functions .<br />

3. Press the button to display MVA -- Y (Master Valve [program A] - Yes [on]).<br />

4. To exclude the selected program from MV/PS operation, press the or button to select<br />

MV[A] – N (Master Valve [program A] – No).<br />

• Master Valve/Pump Start Operation by Station<br />

1. Press the button to display MVS -- N (Master Valve Stations – No).<br />

2. To access this option, the option must first be enabled by pressing the<br />

or button to select MVS -- Y (Yes). By default, all station identifiers will be solid circles<br />

(all enabled).<br />

3. Press the button to select MV -- Y 01 (Master Valve--Yes, station 01).<br />

The station identifier will begin flashing.<br />

4. Press the button to exclude selected station, or press the button to skip the station.<br />

When excluded, the station identifier will change from solid to hollow. The next station identifier<br />

in sequence will begin flashing.<br />

5. Repeat the procedure in step 4 as needed for each station.<br />

• To Set Pump Delay<br />

This feature enables a delay period from 1 to 60 seconds to occur after the MS/PS circuit is activated,<br />

and prior to the start of the first station in the watering sequence. This delay feature is often used in<br />

conjunction with the Station Delay (SD) feature.<br />

1. Set the Program Switch to select program A, B, C, or D.<br />

2. Turn the Function Dial to Special Functions .<br />

3. Press the button (as needed) to display PD -- -- (Pump Delay Off).<br />

4 . Press the or button to select the delay time value from 01 to 60 seconds.<br />

• To Set Pump Enable<br />

This feature allows you to enable or disable MV/PS operation for the duration of a Station Delay<br />

period.<br />

1. Set the Program Switch to select program A, B, C, or D.<br />

2. Turn the Function Dial to Special Functions .<br />

3. Press the button as needed to display PE - - N (Pump Enable - No [Off]).<br />

4. Press the or button to select PE - - Y (Pump Enable - Yes [On]).<br />

11