19.08.2013 Views

Pacom Hardware Manual.book

Pacom Hardware Manual.book

Pacom Hardware Manual.book

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Pacom</strong> Field Controller 1058<br />

Quick Install<br />

GND<br />

OUTPUT 4<br />

OUTPUT 3<br />

+12VDC<br />

OUTPUT 2<br />

OUTPUT 1<br />

INPUT 8<br />

GND<br />

INPUT 7<br />

INPUT 6<br />

GND<br />

INPUT 5<br />

INPUT 4<br />

GND<br />

INPUT 3<br />

INPUT 2<br />

INPUT 1<br />

J2<br />

J1<br />

J3<br />

J4<br />

LK1<br />

Input Wiring<br />

Tamper<br />

BDM<br />

Device<br />

Line<br />

Diagnostic<br />

Port<br />

EOL SIP Resistor Pack<br />

(Can be changed to<br />

match EOL Resistance)<br />

Open Collector Output Wiring<br />

Output 3 and 4 are source to GND<br />

The 1030-007 Dual relay board can be<br />

used to add relays to the outputs.<br />

EARTH GND<br />

SW1<br />

on<br />

off<br />

1 2 3 4<br />

Communications Links<br />

LK7, LK8 & LK9 - RAP (DB9) Port Communications (as follows)<br />

BATTERY<br />

(12VDC)<br />

Note: LNK7 is for RS485 Termination - install all 3 links if first or last device<br />

LNK 9 If installed, puts 12V DC on pin 1 of RAP (DB9) port<br />

LNK 10 If installed, puts 12V DC on pin 25 of Network (DB25) port<br />

Switch SW1 - Normal Position is all off<br />

Dip# Position Function (on panel reset only)<br />

1 ON Clear all parameters (except card-access)<br />

2 ON Read from external EEPROM (if present)<br />

3 ON Copy on-board RAM to expanded RAM board<br />

4 ON Clear card-access parameters<br />

1 and 4 ON Default the panel<br />

LEDs<br />

LNK6<br />

LK2<br />

E1<br />

RL1<br />

RL2<br />

RS485<br />

LNK7<br />

J6<br />

LD1<br />

LD2<br />

LNK8<br />

Mezz Slot<br />

RS232 TTL<br />

LED 1 RED - Output 2 relay energized<br />

LED 2 RED - Output 1 relay energized<br />

LED 3 FLASHING RED - Battery low<br />

RED - On battery power<br />

GREEN - Battery fully charged<br />

and running on AC<br />

AMBER - Battery on fast charge<br />

and running on AC<br />

LED 7 GREEN and RED - Ethernet online<br />

System S ta tu s<br />

Flash green = Normal (AC power)<br />

Off or red = System not running<br />

Flashing red = DC power (input or battery)<br />

or not monitoring AC power<br />

_<br />

Output<br />

Device<br />

+<br />

+<br />

J1<br />

LD3<br />

F1 - BATT<br />

3A<br />

LK4 & LK5 - OPEN - Recommended position for USA, Canada, Singapore,<br />

China and others<br />

CLOSED Recommended position for Australia, Europe, &<br />

New Zealand (to meet TELCO requirements).<br />

Earth Wiring<br />

Earth Wiring required for UL<br />

800 050 002 June, 2008 Version 2.0<br />

GND<br />

OUT4<br />

OUT3<br />

+15V<br />

LED 4 RED - Power on<br />

LED 5 RED - Modem Rx<br />

LED 6 RED - Modem Tx<br />

LED 8 RED - RAP Rx<br />

LED 9 RED - RAP Tx<br />

LED 10 RED - Net CTS<br />

LED 11 RED - Net Rx<br />

LED 12 RED - Net RTS<br />

LED 13 RED - Net Tx<br />

_<br />

J10<br />

F2 - AC<br />

2A<br />

J11<br />

E<br />

15-18VAC<br />

INPUT<br />

F3 - DC<br />

2A<br />

J12<br />

N A +<br />

+<br />

+<br />

_<br />

_<br />

LNK 1 or 2<br />

GND +15V<br />

Output<br />

Device<br />

+<br />

LNK 1 or 2<br />

GND +15V<br />

LD4<br />

12-15VDC<br />

INPUT<br />

Normally Open with<br />

on-board power<br />

E3<br />

Normally Closed with<br />

on-board power<br />

Normally Open with power supply Normally Closed with power supply<br />

Normally Open with power supply<br />

(common GND to 1058)<br />

J1<br />

J2<br />

_<br />

LD5<br />

Reset<br />

Switch<br />

Relay Output Wiring<br />

Output<br />

Device<br />

+<br />

External<br />

Power Supply<br />

_<br />

_<br />

Output<br />

Device<br />

_<br />

J1<br />

J2<br />

LD7<br />

E2<br />

LD6<br />

LD8<br />

LD10<br />

LD11<br />

LK10<br />

LD12<br />

LD9 LD13<br />

LK6 LK8<br />

LK7<br />

GND<br />

OUT4<br />

OUT3<br />

+15V<br />

External<br />

Power Supply<br />

+<br />

REL NO<br />

COM<br />

REL NC<br />

J2<br />

REL NO<br />

COM<br />

REL NC<br />

LNK 1 or 2<br />

GND +15V<br />

GND<br />

OUT4<br />

OUT3<br />

+15V<br />

REL NO<br />

COM<br />

REL NC<br />

LK9<br />

_<br />

LNK 1 or 2<br />

GND +15V<br />

Output<br />

Device<br />

+<br />

LNK 1 or 2<br />

GND +15V<br />

+<br />

+<br />

_<br />

Output<br />

Device<br />

+<br />

Output<br />

Device<br />

PIN 6<br />

GND<br />

External<br />

Power Supply<br />

_<br />

_<br />

J1<br />

J2<br />

Phone<br />

Port<br />

Network<br />

Port<br />

RAP<br />

Port<br />

Ethernet<br />

Port<br />

RAP Port RS485 Wiring<br />

Pin 1 +12VDC<br />

Pin 2 +485<br />

Pin 3 -485<br />

Pin 5 GND<br />

GND<br />

OUT4<br />

OUT3<br />

+15V<br />

REL NO<br />

COM<br />

REL NC<br />

REL NO<br />

COM<br />

REL NC<br />

Normally Closed with power supply<br />

(common GND to 1058)<br />

J2<br />

_<br />

External<br />

Power Supply<br />

J1<br />

J2<br />

+<br />

LNK 1 or 2<br />

GND +15V<br />

GND<br />

OUT4<br />

OUT3<br />

+15V<br />

REL NO<br />

COM<br />

REL NC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!