arcmaster 400 s - Victor Technologies
arcmaster 400 s - Victor Technologies
arcmaster 400 s - Victor Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ARCMASTER <strong>400</strong> S<br />
3.04 Specifi cations<br />
3-4<br />
Parameter<br />
Rated Output<br />
<strong>400</strong> S<br />
Amperes <strong>400</strong><br />
Volts 36<br />
Duty Cycle 25%<br />
<strong>400</strong>A / 26V @ 25%<br />
TIG 300A / 22V @ 60%<br />
Duty Cycle<br />
300A / 18V @ 100%<br />
<strong>400</strong>A / 36V @ 25%<br />
STICK 300A / 32V @ 60%<br />
200A / 28V @ 100%<br />
Output Current Range<br />
TIG<br />
STICK<br />
5 – <strong>400</strong>A<br />
Open Circuit Voltage<br />
Dimensions<br />
65V<br />
Width 8.3” (210mm)<br />
Height 16.5” (420mm)<br />
Length 17.7” (450mm)<br />
Weight 441.1 lb. 20 kg.<br />
Output @ Rated Load Three-phase Single-phase<br />
Rated Input Voltage 208-230/460V 208-230V<br />
Output Amperes <strong>400</strong>A 300A<br />
Output Volts 36V 32V<br />
Duty Cycle 25% 25%<br />
KVA 24.0kVA 20.0kVA<br />
KW<br />
Output @ No Load<br />
18.0kW 12.0kW<br />
KVA 0.5<br />
KW 0.13<br />
Amperage Draw<br />
Input Volts Three Phase @ Rated Load No Load<br />
208V 67 1.4<br />
230V 61 1.3<br />
460V<br />
Input Volts Single Phase<br />
31 0.7<br />
208V 97 2.4<br />
230V 87 2.2<br />
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change,<br />
improve or revise the specifi cations or design of this or any product without prior notice. Such updates or changes do<br />
March 31, 2006