SECTION 12:<br />
POWER SOURCE ERROR CODES<br />
Description Possible Cause Remedy Remarks<br />
E01 error code displayed A The Welding Power Source’s duty cycle A Let Power Source cool down then keep Weld current ceases.<br />
has been exceeded.<br />
within its duty cycle.<br />
Temperature sensor TH1 (protects B Fan ceases to operate. B Have an Accredited Thermal Arc Buzzer sounds constantly.<br />
IGBTs) is greater than 80ºC for<br />
Service Agent investigate<br />
C Air flow is restricted by vents being C Unblock vents then let Power Source Fan operates at max speed.<br />
blocked<br />
cool down.<br />
E01 resets when TH1 decreases to<br />
70ºC for about 30 seconds.<br />
E02 error code displayed A The Welding Power Source’s duty cycle A Let Power Source cool down then keep Weld current ceases.<br />
has been exceeded.<br />
within its duty cycle.<br />
Temperature sensor TH2 (protects B Fan ceases to operate. B Have an Accredited Thermal Arc Buzzer sounds constantly.<br />
secondary diodes) is greater than<br />
Service Agent investigate<br />
80ºC for about 1 second<br />
C Air flow is restricted by vents being C Unblock vents then let Power Source Fan operates at max speed.<br />
blocked<br />
cool down.<br />
E02 resets when TH1 decreases to<br />
70ºC for about 30 seconds.<br />
1<br />
2<br />
ARCMASTER <strong>400</strong> S<br />
March 31, 2006 12-1<br />
A Reduce length of welding arc. Weld current ceases.<br />
E03 error code displayed A Primary current is too high because<br />
welding arc is too long.<br />
3<br />
Buzzer sounds constantly.<br />
B Have an Accredited Thermal Arc<br />
Service Agent or a qualified electrician<br />
check for low Mains voltage.<br />
Primary (input) current too high B Mains supply voltage is more than 10%<br />
below nominal voltage<br />
Switch machine off then on to reset<br />
E03 error.<br />
E11 error code displayed Primary supply voltage is greater than Have an Accredited Thermal Arc Weld current ceases.<br />
the nominal voltage plus 10%<br />
Service Agent or a qualified electrician<br />
check the Primary voltage.<br />
Over Primary supply (input) voltage<br />
Buzzer sounds constantly.<br />
at primary capacitors is exceeded<br />
for one second<br />
Error code E11 automatically will<br />
reset when the voltage reduces.<br />
4