<strong>Configuration</strong><br />

The current configuration <strong>of</strong> <strong>the</strong> <strong>CAN</strong>-<strong>CBM</strong>-<strong>Bridge</strong> module from <strong>the</strong> previous examples can be<br />

displayed by means <strong>of</strong> command R.<br />

Input: R >Enter<<br />

Output: B0:6<br />

I0:200 I1:300<br />

I0:23456789 I1:543<br />

M0:1:0000000000000000000000xxxxxxx1<br />

B1:D<br />

I1:24567893 I0:205<br />

E After <strong>the</strong> configuration has been successfully completed, <strong>the</strong> configured data<br />

is stored in <strong>the</strong> configuration memory by means <strong>of</strong> command E. Only after<br />

<strong>the</strong> data has been stored <strong>the</strong> changes become effective.<br />

The <strong>CAN</strong>-<strong>CBM</strong>-<strong>Bridge</strong> module is now in RUN status and meets <strong>the</strong> desired<br />

bridge function.<br />

Input: E >Enter<<br />

C You can delete a configuration again by means <strong>of</strong> <strong>the</strong> command C. The<br />

command deletes all identifier assignments and resets <strong>the</strong> <strong>CAN</strong> bit rates to<br />

<strong>the</strong> default value <strong>of</strong> HexIndex 6, that is a bit rate <strong>of</strong> 125 kbit/s. The<br />

configuration memory is also deleted.<br />

Input: C >Enter<<br />