<strong>Configuration</strong><br />
The current configuration <strong>of</strong> <strong>the</strong> <strong>CAN</strong>-<strong>CBM</strong>-<strong>Bridge</strong> module from <strong>the</strong> previous examples can be<br />
displayed by means <strong>of</strong> command R.<br />
Input: R >Enter<<br />
Output: B0:6<br />
I0:200 I1:300<br />
I0:23456789 I1:543<br />
M0:1:0000000000000000000000xxxxxxx1<br />
B1:D<br />
I1:24567893 I0:205<br />
E After <strong>the</strong> configuration has been successfully completed, <strong>the</strong> configured data<br />
is stored in <strong>the</strong> configuration memory by means <strong>of</strong> command E. Only after<br />
<strong>the</strong> data has been stored <strong>the</strong> changes become effective.<br />
The <strong>CAN</strong>-<strong>CBM</strong>-<strong>Bridge</strong> module is now in RUN status and meets <strong>the</strong> desired<br />
bridge function.<br />
Input: E >Enter<<br />
C You can delete a configuration again by means <strong>of</strong> <strong>the</strong> command C. The<br />
command deletes all identifier assignments and resets <strong>the</strong> <strong>CAN</strong> bit rates to<br />
<strong>the</strong> default value <strong>of</strong> HexIndex 6, that is a bit rate <strong>of</strong> 125 kbit/s. The<br />
configuration memory is also deleted.<br />
Input: C >Enter<<br />
<strong>CAN</strong>-<strong>CBM</strong>-BRIDGE/2 Hardware Rev. 1.2 17