Version 3.1<br />
June 2011<br />
Camera View 1 Camera View 2<br />
Figure 14: Required camera views<br />
10.2.1.4 For either on-board or off-board camera systems, care should be taken to ensure that that<br />
camera placement is perpendicular to the direction of sled travel. Camera measurements<br />
should be taken to the film plane of the camera, from both the fixed targets and the head<br />
centre of Gravity target.<br />
10.2.1.5 For on-board camera views, it should be ensured that the camera mounting systems are<br />
suitably robust so as to prevent camera shake during the test. Target tracking<br />
compensation must be included to correct for some small degrees of camera movement.<br />
10.2.1.6 For off board camera views, compensation must be included in the film analysis to take<br />
account of parallax effects due to sled motion relative to the cameras.<br />
10.2.2 Video Motion Targets<br />
10.2.2.1 In order to monitor and measure the motion of the seat and dummy, film targets should<br />
be applied to both seat and ATD. Targets should be securely affixed to areas of the seat<br />
which will not be deformed by the ATD during the test.<br />
10.2.2.2 The following targets should be applied the BioRID, seat and sled to monitor the head<br />
and seat back during the test. The required target definitions are illustrated in Figure 15<br />
and are given along with their reference points in Table 3.<br />
10.2.2.3 In order to track the trajectories of the ATD and seat with reference to the sled the<br />
following dimensions should be recorded. All measurements shall be measured from the<br />
camera film plane to the reference targets and recorded in mm. See Figure 16 and Table<br />
4.<br />
32