Version 3.1<br />

June 2011<br />

Zero to 4mm gap<br />

between H-PM back<br />

pan and jig support<br />

Figure 6. H-PM installed into the jig without HRMD assembly. A check should be made to ensure that the gap between the<br />

H-PM back pan and jig vertical support is no more than 4mm.<br />

7. Installation of HRMD<br />

7.1 Install the HRMD unit with the backset and height probes pre-installed onto the H-PM<br />

assembly as per HRMD User Manual ICBC 1999<br />

7.2 Ensure that the plungers fitted to the centre locator fork on the HRMD are in good condition<br />

and that they are tight enough to allow the fork to contact the rear surface of the H-PM weight hanger<br />

support.<br />

7.3 Level the HRMD head using the adjuster knob and the integral spirit level. Confirm that the<br />

spirit level is accurate by checking that the rear surface of the head is vertical (± 0.3) with a<br />

calibrated digital inclinometer. If not than adjust the head using the adjuster knob and digital<br />

inclinometer until vertical. The integral spirit level should then be adjusted or replaced as appropriate.<br />

7.4 Check the trueness of the head bubble level. Place a digital inclinometer on the rear surface of<br />

the head and adjust the bubble to level using the screw. The bubble must not then be altered during the<br />

remaining calibration procedure or during use.<br />

48