Version 3.1<br />

June 2011<br />

Figure 8. HRMD with backset and height calibration<br />

9. Attachment of Torso Angle Measuring Surface<br />

9.1 Measure the trunk of the left hand weight hanger with a digital inclinometer.<br />

Figure 9. Measurement being taken of the torso angle at the weight hanger trunk by a digital inclinometer.<br />

9.2 A calibrated Angle Measuring surface block should then be attached to ensure the left hand<br />

weight hanger trunk to ensure that an angle of 90 (± 0.3 is indicated).<br />

9.3 If the angle of the left hand weight hanger is not at 90 (± 0.3) then a calibrated and adjusted<br />

surface block should be installed in place of the standard item.<br />