Whiplash Testing Protocol - Euro NCAP
Whiplash Testing Protocol - Euro NCAP
Whiplash Testing Protocol - Euro NCAP
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Version 3.1<br />
June 2011<br />
Figure 7. H-PM in calibration jig with H-point to arm supports<br />
8. Calibration of the H-PM/HRMD Unit<br />
Once the H-PM/HRMD assembly is installed into the jig the following measures (with tolerances)<br />
should be taken:<br />
8.1 Adjust the HRMD height probe until it is in contact with the forward surface of the jig vertical<br />
support. If the lower surface of the height probe contacts the scale at 0mm (±1mm) it is deemed to be<br />
within calibration. If this is not possible then the entire HRMD unit should be checked by the<br />
manufacturer (ICBC).<br />
8.2 Adjust the HRMD backset probe to contact the forward surface of the jig vertical support. The<br />
indicated backset should read 8cm (±1mm). If this is not possible then the entire HRMD unit should<br />
be returned to the manufacturer.<br />
49