Figure 7. H-PM in calibration jig with H-point to arm supports<br />

8. Calibration of the H-PM/HRMD Unit<br />

Once the H-PM/HRMD assembly is installed into the jig the following measures (with tolerances)<br />

should be taken:<br />

8.1 Adjust the HRMD height probe until it is in contact with the forward surface of the jig vertical<br />

support. If the lower surface of the height probe contacts the scale at 0mm (±1mm) it is deemed to be<br />

within calibration. If this is not possible then the entire HRMD unit should be checked by the<br />

manufacturer (ICBC).<br />

8.2 Adjust the HRMD backset probe to contact the forward surface of the jig vertical support. The<br />

indicated backset should read 8cm (±1mm). If this is not possible then the entire HRMD unit should<br />

be returned to the manufacturer.<br />

49