General information<br />
Requirements for installation<br />
Wall height of at least 650 mm (only in special cases with a minimal<br />
window-sill a lower wall height (> 625 mm) may suffice).<br />
Inner leaf of cavity wall must be strong enough to support the<br />
reclinable radiator.<br />
Rigid and strong wall construction for attachment of the radiatorsupports.<br />
No plumbing pipes or steel constructions in the wall where airducts<br />
will be drilled.<br />
The ClimaRad must be able to blow out air upward unhindered.<br />
At lower wall heights the window-sill may not protrude beyond the<br />
frontside of the ClimaRad ventilation-unit. Therefore the window-sill<br />
may not be deeper than approx. 104 mm (measured from the inside<br />
wall surface, see figure 1B).<br />
The outer wall must be reachable to install and maintain the<br />
external duct-grills.<br />
Tools and fixing materials<br />
ClimaRad drilling template.<br />
Drill Ø 112 mm, heavy drill suited for the wall to be drilled<br />
Stone/concrete drill bit Ø 6 mm.<br />
Stone/concrete drill bit Ø 10 mm.<br />
Levelling rod.Pencil.<br />
Spanners 10 mm, 13 mm.<br />
Extension set socket 10.<br />
PUR-spray.<br />
Battery-driven drill with bits.<br />
Cross-head screwdriver.