01.10.2013 Views

Numerical modelin of floating prefabricated vertical drains in layered ...

Numerical modelin of floating prefabricated vertical drains in layered ...

Numerical modelin of floating prefabricated vertical drains in layered ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The excess pore-pressure distribution along the 12<br />

meters <strong>of</strong> s<strong>of</strong>t clay layers after the construction <strong>of</strong> the 4.0<br />

meter fill material is visualized <strong>in</strong> Figure 4. The development<br />

<strong>of</strong> the settlements and the excess pore pressures<br />

obta<strong>in</strong>ed from the numerical model is shown <strong>in</strong> figure<br />

5 for all four conditions. As expected, the <strong>in</strong>stallation <strong>of</strong><br />

the PVD significantly decreased the consolidation time,<br />

whereas consider<strong>in</strong>g the smear effects has the opposite<br />

effect and, therefore, <strong>in</strong> order to arrive at realistic predictions,<br />

this effect has to be taken <strong>in</strong>to account.<br />

The settlement plate was <strong>in</strong>stalled and measurements<br />

started after the <strong>in</strong>stallation <strong>of</strong> the 1.0 meter sand<br />

Excess Pore Pressure (KPa)<br />

-10<br />

-20<br />

-30<br />

-40<br />

-50<br />

-60<br />

-70<br />

-80<br />

I. IKHYA & H. F. SCHWEIGER: NUMERICAL MODELING OF FLOATING PREFABRICATED VERTICAL DRAINS IN LAYERED SOIL<br />

blanket and the <strong>dra<strong>in</strong>s</strong>, so no settlement read<strong>in</strong>gs were<br />

taken for this stage <strong>of</strong> the construction. The settlements<br />

obta<strong>in</strong>ed from the numerical prediction and measured<br />

<strong>in</strong> the field are compared <strong>in</strong> figure 6. It can be seen that<br />

a good agreement between the field measurement and<br />

the numerical prediction could be achieved, for both<br />

full and partial penetration (L/H=0.7) <strong>of</strong> the PVD when<br />

tak<strong>in</strong>g the smear effect <strong>in</strong>to account. It is clear that the<br />

length <strong>of</strong> the dra<strong>in</strong> can be reduced by up to 30% without<br />

significantly affect<strong>in</strong>g the consolidation process for<br />

double dra<strong>in</strong>age—two soil-layer conditions when the<br />

second layer is stiffer and has a higher permeability than<br />

the first layer.<br />

Figure 4. Excess pore-pressure distribution after the placement <strong>of</strong> 4.0 meter fill material.<br />

Axisymmetric Model <strong>of</strong> Cirebon Power Plant Embankment<br />

1 10 100 1000 10000<br />

0<br />

Time (days)<br />

Without PVD<br />

Only PVD<br />

PVD+Smear<br />

Float<strong>in</strong>g PVD (L/H=0.7)<br />

Figure 5. Excess pore-pressure and consolidation curves for all conditions.<br />

Vertical Displacement (m)<br />

1 10 100 1000 10000<br />

0<br />

-0.1<br />

-0.2<br />

-0.3<br />

-0.4<br />

-0.5<br />

-0.6<br />

-0.7<br />

-0.8<br />

Axisymmetric Model <strong>of</strong> Cirebon Power Plant Embankment<br />

Time (days)<br />

Without PVD<br />

Only PVD<br />

PVD+Smear<br />

Float<strong>in</strong>g PVD (L/H=0.7)<br />

ACTA GEOTECHNICA SLOVENICA, 2012/2 29.