Setup / Config mode operation and channel selection<br />

How to set the channel:<br />

1. While Central and Remote units are still powered up on the bench, check dip<br />

switches 2,3,4 to make sure they are set to the required address. Switches 2,3,4 are all<br />

Off for the default channel 0 (zero).<br />

2. On the Remote unit, move DIP switch 1 to the Service / Config (ON) position.<br />

a. The unit will reset.<br />

b. The Amber com led will flash momentarily, then go dark.<br />

c. The diagnostic LED will flash Red twice.<br />

d. The diagnostic LED will flash green on and off about once per second.<br />

The Remote unit is now in Setup mode.<br />

3. On the Central unit, move DIP switch 1 to the Service / Config (ON) position.<br />

a. The unit will reset.<br />

BENCH TEST UNITS - Configuration Mode<br />

b. The Amber com led will flash rapidly on both the Central and Remote units.<br />

c. The diagnostic LED will flash green on and off about once per second.<br />

The addresses selected by the DIP switches will be loaded into memory. Make sure<br />

Central and Remote units are set to the SAME address!<br />