Model “LT”<br />

On model “LT” following sensors are installed::<br />

(1) The proximity switch is placed between P1<br />

Platform scissors to stop the lift at the<br />

safety height (400 mm);<br />

(2) the proximity switch is placed between P2<br />

platform scissors to stop the lift at the<br />

maximum height<br />

(3) The leveling system limit switch for platform<br />

P1 is under the runway on left external side.<br />

(4) The leveling system limit switch for platform<br />

P2 is under the runway on right external side.<br />

(5) The photocell is locate don internal side of<br />

platform P1.<br />

(6) The reflector is located in the internal side of<br />

platform P2<br />

(9) Safety height (130 mm) for auxiliary lift sensor<br />

is installed on arms of platform P1<br />

(10) Auxiliary lift platform P1 leveling sensor, is<br />

installed on of auxiliary lift platform P1 base<br />

frame;<br />

(11) Auxiliary lift maximum height limit switch, is<br />

installed on of auxiliary lift external arm P2;<br />

(12) Auxiliary lift platform P2 leveling sensor, is<br />

installed on of auxiliary lift platform P2 base<br />

frame;<br />

Model “LTAT”<br />

On model “LTAT” following sensors are installed::<br />

(1) The proximity switch is placed between P1<br />

Platform scissors to stop the lift at the<br />

safety height (400 mm);<br />

(2) the proximity switch is placed between P2<br />

platform scissors to stop the lift at the<br />

maximum height<br />

(3) The leveling system limit switch for platform P1 is<br />

under the runway on left external side.<br />

(4) The leveling system limit switch for platform P2 is<br />

under the runway on right external side.<br />

(5) The photocell is locate don internal side of platform<br />

P1.<br />

(6) The reflector is located in the internal side of platform<br />

P2<br />

(7) Limit switch for 1 st working position is located on<br />

internal arm of platform P1<br />

(8) Limit switch for 2 nd working position is located on<br />

internal arm of platform P2<br />

(9) Safety height (130 mm) for auxiliary lift sensor is<br />

installed on arms of platform P1<br />

(10) Auxiliary lift platform P1 leveling sensor, is installed<br />

on of auxiliary lift platform P1 base frame;<br />

(11) Auxiliary lift maximum height limit switch, is<br />

installed on of auxiliary lift external arm P2;<br />

(12) Auxiliary lift platform P2 leveling sensor, is installed<br />

on of auxiliary lift platform P2 base frame